MIL-DTL-26666G
HOSE ASSEMBLY, PNEUMATIC, HIGH PRESSURE
Organization:
DLA - CC - DLA Land and Maritime
Year: 2006
Abstract: This specification covers the requirements for a hose assembly, pneumatic, high pressure having a nominal working pressure of 4,000 psig (275.79 bar) in the operating temperature range of -65 to +160°F (-53.89°C to 71.11°C). DO NOT USE FOR OXYGEN. DO NOT USE ON AIRCRAFT. Intended Use: The hose assembly covered by this specification is intended for use as a component of high-pressure pneumatic ground support equipment used in aircraft ground servicing and engine starting applications. The hose assembly is military unique because it must have a minimum tensile strength of 1,000 pounds (453.59 kg) and must be able to be flexed through 180° at a specified bend radius at a temperature or -65°F (-53.89°C). Commercial hoses do not have these requirements and would experience catastrophic damage. (DO NOT USE FOR OXYGEN.)
Subject: 4000 psig
Collections
:
Show full item record
| contributor author | DLA - CC - DLA Land and Maritime | |
| date accessioned | 2017-09-04T18:01:22Z | |
| date available | 2017-09-04T18:01:22Z | |
| date copyright | 39061 | |
| date issued | 2006 | |
| identifier other | FZFSXBAAAAAAAAAA.pdf | |
| identifier uri | https://yse.yabesh.ir/std/handle/yse/184477 | |
| description abstract | This specification covers the requirements for a hose assembly, pneumatic, high pressure having a nominal working pressure of 4,000 psig (275.79 bar) in the operating temperature range of -65 to +160°F (-53.89°C to 71.11°C). DO NOT USE FOR OXYGEN. DO NOT USE ON AIRCRAFT. Intended Use: The hose assembly covered by this specification is intended for use as a component of high-pressure pneumatic ground support equipment used in aircraft ground servicing and engine starting applications. The hose assembly is military unique because it must have a minimum tensile strength of 1,000 pounds (453.59 kg) and must be able to be flexed through 180° at a specified bend radius at a temperature or -65°F (-53.89°C). Commercial hoses do not have these requirements and would experience catastrophic damage. (DO NOT USE FOR OXYGEN.) | |
| language | English | |
| title | MIL-DTL-26666G | num |
| title | HOSE ASSEMBLY, PNEUMATIC, HIGH PRESSURE | en |
| type | standard | |
| page | 15 | |
| status | Active | |
| tree | DLA - CC - DLA Land and Maritime:;2006 | |
| contenttype | fulltext | |
| subject keywords | 4000 psig |