IEEE 1673

Requirements for Conduit and Cable Seals for Field Connected Wiring to Equipment in Petroleum and Chemical Industry Exposed to Pressures above Atmospheric (1.5 kPa, 0.22 psi)

Organization:
IEEE - The Institute of Electrical and Electronics Engineers, Inc.
Year: 2015

Abstract: This document provides specific requirements for field installed sealing between a pressurized system (stream) containing flammable or combustible process fluids which is connected directly or indirectly to an electrical system where a failure could allow the migration of process fluids directly into the electrical system.
The basic requirements for electrical safety are not specifically addressed by this standard. The effects of the loss of containment of the process system in terms of risk to the environment and/or personnel health and safety are also not addressed by this document.
Purpose
The purpose of this document is to provide construction and performance requirements for sealing devices that are designed to prevent flammable or combustible process fluids from entering the electrical wiring system and to prevent the propagation of an explosion through the cable or conduit system. While certain incorporate a primary seal in their design, a redundant sealing method or secondary seal as defi ned in NFPA 70® NEC® (501.17, 505.26) and CSA® C22.1 (18-072) is required to provide a backup in the event of the failure of the primary seal. These seals are intended for fi eld installation by qualifi ed individuals.
URI: https://yse.yabesh.ir/std/handle/yse/185085
Collections :
  • IEEE - The Institute of Electrical and Electronics Engineers, Inc.
  • Download PDF : (1.386Mb)
  • Show Full MetaData Hide Full MetaData
  • Statistics

    IEEE 1673

Show full item record

contributor authorIEEE - The Institute of Electrical and Electronics Engineers, Inc.
date accessioned2017-09-04T18:02:07Z
date available2017-09-04T18:02:07Z
date copyright2015.12.05
date issued2015
identifier otherGAXKOFAAAAAAAAAA.pdf
identifier urihttps://yse.yabesh.ir/std/handle/yse/185085
description abstractThis document provides specific requirements for field installed sealing between a pressurized system (stream) containing flammable or combustible process fluids which is connected directly or indirectly to an electrical system where a failure could allow the migration of process fluids directly into the electrical system.
The basic requirements for electrical safety are not specifically addressed by this standard. The effects of the loss of containment of the process system in terms of risk to the environment and/or personnel health and safety are also not addressed by this document.
Purpose
The purpose of this document is to provide construction and performance requirements for sealing devices that are designed to prevent flammable or combustible process fluids from entering the electrical wiring system and to prevent the propagation of an explosion through the cable or conduit system. While certain incorporate a primary seal in their design, a redundant sealing method or secondary seal as defi ned in NFPA 70® NEC® (501.17, 505.26) and CSA® C22.1 (18-072) is required to provide a backup in the event of the failure of the primary seal. These seals are intended for fi eld installation by qualifi ed individuals.
languageEnglish
titleIEEE 1673num
titleRequirements for Conduit and Cable Seals for Field Connected Wiring to Equipment in Petroleum and Chemical Industry Exposed to Pressures above Atmospheric (1.5 kPa, 0.22 psi)en
typestandard
page16
statusActive
treeIEEE - The Institute of Electrical and Electronics Engineers, Inc.:;2015
contenttypefulltext
DSpace software copyright © 2017-2020  DuraSpace
نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
yabeshDSpacePersian
 
DSpace software copyright © 2017-2020  DuraSpace
نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
yabeshDSpacePersian