CSA C22.2 NO. 269.2-13

Surge protective devices - Type 2 - Permanently connected - First Edition

Organization:
CSA - CSA Group
Year: 2013

Abstract: This Standard applies to surge protective devices (SPDs) intended for
) permanently connected applications designed for limiting surge voltages and discharging surge currents;
b) use on 50/60 Hz circuits over 42 V and up to 750 V ac;
c) installation on the load side of the main overcurrent protective device; and
d) indoor or outdoor use in accordance with the Canadian Electrical Code, Part I.
Equipment designed solely for other power disturbances such as notches, sags, and noise is not within the scope of this document.
SPDs discussed in this Standard contain at least one voltage limiting or voltage switching component for diverting surge currents or dissipating surge energy, or both. Examples of such components are metal oxide varistors, silicon avalanche diodes, spark gaps and gas discharge tubes. Ferroresonators, motorgenerators, uninterruptible power supplies, and filters containing only inductive or capacitive components are not considered SPDs in this standard.
General requirements applicable to this Standard are given in the latest edition of CAN/CSA-C22.2 No. 0
In CSA standards, "shall" is used to express a requirement, i.e., a provision that the user is obliged to satisfy in order to comply with the standard; "should" is used to express a recommendation or that which is advised but not required; and "may" is used to express an option or that which is permissible within the limits of the standard.
Notes accompanying clauses do not include requirements or alternative requirements; the purpose of a note accompanying a clause is to separate from the text explanatory or informative material.
Notes to tables and figures are considered part of the table or figure and may be written as requirements.
Annexes are designated normative (mandatory) or informative (nonmandatory) to define their application.
URI: https://yse.yabesh.ir/std/handle/yse/187520
Collections :
  • CSA - CSA Group
  • Download PDF : (1.008Mb)
  • Show Full MetaData Hide Full MetaData
  • Statistics

    CSA C22.2 NO. 269.2-13

Show full item record

contributor authorCSA - CSA Group
date accessioned2017-09-04T18:04:33Z
date available2017-09-04T18:04:33Z
date copyright2013.06.01
date issued2013
identifier otherGHHTEFAAAAAAAAAA.pdf
identifier urihttps://yse.yabesh.ir/std/handle/yse/187520
description abstractThis Standard applies to surge protective devices (SPDs) intended for
) permanently connected applications designed for limiting surge voltages and discharging surge currents;
b) use on 50/60 Hz circuits over 42 V and up to 750 V ac;
c) installation on the load side of the main overcurrent protective device; and
d) indoor or outdoor use in accordance with the Canadian Electrical Code, Part I.
Equipment designed solely for other power disturbances such as notches, sags, and noise is not within the scope of this document.
SPDs discussed in this Standard contain at least one voltage limiting or voltage switching component for diverting surge currents or dissipating surge energy, or both. Examples of such components are metal oxide varistors, silicon avalanche diodes, spark gaps and gas discharge tubes. Ferroresonators, motorgenerators, uninterruptible power supplies, and filters containing only inductive or capacitive components are not considered SPDs in this standard.
General requirements applicable to this Standard are given in the latest edition of CAN/CSA-C22.2 No. 0
In CSA standards, "shall" is used to express a requirement, i.e., a provision that the user is obliged to satisfy in order to comply with the standard; "should" is used to express a recommendation or that which is advised but not required; and "may" is used to express an option or that which is permissible within the limits of the standard.
Notes accompanying clauses do not include requirements or alternative requirements; the purpose of a note accompanying a clause is to separate from the text explanatory or informative material.
Notes to tables and figures are considered part of the table or figure and may be written as requirements.
Annexes are designated normative (mandatory) or informative (nonmandatory) to define their application.
languageEnglish
titleCSA C22.2 NO. 269.2-13num
titleSurge protective devices - Type 2 - Permanently connected - First Editionen
typestandard
page53
statusActive
treeCSA - CSA Group:;2013
contenttypefulltext
DSpace software copyright © 2017-2020  DuraSpace
نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
yabeshDSpacePersian
 
DSpace software copyright © 2017-2020  DuraSpace
نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
yabeshDSpacePersian