IEEE C57.19.00

General Requirements and Test Procedure for Outdoor Power Apparatus Bushings

Organization:
IEEE - The Institute of Electrical and Electronics Engineers, Inc.
Year: 2004

Abstract: This standard applies to power apparatus bushings that have basic impulse insulation levels of 110 kV and above for use as components of oil-filled transformers and oil-filled reactors.
This standard does not apply to the following:
— High-voltage cable terminations (potheads)
— Bushings for oil circuit breakers
— Bushings for instrument transformers
— Bushings for test transformers
— Bushings in which the internal insulation is provided by a gas
— Bushings applied with gaseous insulation (other than air at atmospheric pressure) external to the bushing
— Bushings for distribution-class circuit breakers and transformers
— Bushings for automatic circuit reclosers and line sectionalizers
— Bushings for oil-less and oil-poor apparatus
— Bushings for dc applications
URI: https://yse.yabesh.ir/std/handle/yse/190074
Subject: apparatus bushings
Collections :
  • IEEE - The Institute of Electrical and Electronics Engineers, Inc.
  • Download PDF : (593.1Kb)
  • Show Full MetaData Hide Full MetaData
  • Statistics

    IEEE C57.19.00

Show full item record

contributor authorIEEE - The Institute of Electrical and Electronics Engineers, Inc.
date accessioned2017-09-04T18:07:07Z
date available2017-09-04T18:07:07Z
date copyright38329
date issued2004
identifier otherGOEBIBAAAAAAAAAA.pdf
identifier urihttps://yse.yabesh.ir/std/handle/yse/190074
description abstractThis standard applies to power apparatus bushings that have basic impulse insulation levels of 110 kV and above for use as components of oil-filled transformers and oil-filled reactors.
This standard does not apply to the following:
— High-voltage cable terminations (potheads)
— Bushings for oil circuit breakers
— Bushings for instrument transformers
— Bushings for test transformers
— Bushings in which the internal insulation is provided by a gas
— Bushings applied with gaseous insulation (other than air at atmospheric pressure) external to the bushing
— Bushings for distribution-class circuit breakers and transformers
— Bushings for automatic circuit reclosers and line sectionalizers
— Bushings for oil-less and oil-poor apparatus
— Bushings for dc applications
languageEnglish
titleIEEE C57.19.00num
titleGeneral Requirements and Test Procedure for Outdoor Power Apparatus Bushingsen
typestandard
page27
statusActive
treeIEEE - The Institute of Electrical and Electronics Engineers, Inc.:;2004
contenttypefulltext
subject keywordsapparatus bushings
subject keywordsbushings
subject keywordsoil-filled reactors
subject keywordsoil-filled transformers