CSA CAN/CSA-C22.2 NO. 60529:05

English -- Degrees of protection provided by enclosures (IP Code) - First Edition;
French -- Degrés de protection procurés par les enveloppes (Code IP) - First Edition

Organization:
CSA - CSA Group
Year: 2010

Abstract: Scope and object
This standard applies to the classification of degrees of protection provided by enclosures for electrical equipment with a rated voltage not exceeding 72,5 kV.
The object of this standard is to give:
a) Definitions for degrees of protection provided by enclosures of electrical equipment as regards:
1) protection of persons against access to hazardous parts inside the enclosure;
2) protection of the equipment inside the enclosure against ingress of solid foreign objects;
3) protection of the equipment inside the enclosure against harmful effects due to the ingress of water.
b) Designations for these degrees of protection.
c) Requirements for each designation.
d) Tests to be performed to verify that the enclosure meets the requirements of this standard.
It will remain the responsibility of individual technical committees to decide on the extent and manner in which, the classification is used in their standards and to define "enclosure" as it applies to their equipment. However, it is recommended that for a given classification the tests do not differ from those specified in this standard. If necessary, complementary requirements may be included in the relevant product standard. A guide for the details to be specified in relevant product standards is given in annex B.
For a particular type of equipment, a technical committee may specify different requirements provided that at least the same level of safety is ensured.
This standard deals only with enclosures that are in all other respects suitable for their intended use as specified in the relevant product standard and which from the point of view of materials and workmanship ensure that the claimed degrees of protection are maintained under the normal conditions of use.
This standard is also applicable to empty enclosures provided that the general test requirements are met and that the selected degree of protection is suitable for the type of equipment to be protected.
Measures to protect both the enclosure and the equipment inside the enclosure against external influences or conditions such as
- mechanical impacts
- corrosion
- corrosive solvents (for example, cutting liquids)
- fungus
- vermin
- solar radiation
- icing
- moisture (for example, produced by condensation)
- explosive atmospheres
and the protection against contact with hazardous moving parts external to the enclosure (such as fans), are matters for the relevant product standard to be protected.
Barriers external to the enclosure and not attached to it and obstacles which have been provided solely for the safety of personnel are not considered as a part of the enclosure and are not dealt with in this standard.
URI: https://yse.yabesh.ir/std/handle/yse/191866
Collections :
  • CSA - CSA Group
  • Download PDF : (991.9Kb)
  • Show Full MetaData Hide Full MetaData
  • Statistics

    CSA CAN/CSA-C22.2 NO. 60529:05

Show full item record

contributor authorCSA - CSA Group
date accessioned2017-09-04T18:08:50Z
date available2017-09-04T18:08:50Z
date copyright2005.07.01 (R 2010)
date issued2010
identifier otherGSXCDFAAAAAAAAAA.pdf
identifier urihttps://yse.yabesh.ir/std/handle/yse/191866
description abstractScope and object
This standard applies to the classification of degrees of protection provided by enclosures for electrical equipment with a rated voltage not exceeding 72,5 kV.
The object of this standard is to give:
a) Definitions for degrees of protection provided by enclosures of electrical equipment as regards:
1) protection of persons against access to hazardous parts inside the enclosure;
2) protection of the equipment inside the enclosure against ingress of solid foreign objects;
3) protection of the equipment inside the enclosure against harmful effects due to the ingress of water.
b) Designations for these degrees of protection.
c) Requirements for each designation.
d) Tests to be performed to verify that the enclosure meets the requirements of this standard.
It will remain the responsibility of individual technical committees to decide on the extent and manner in which, the classification is used in their standards and to define "enclosure" as it applies to their equipment. However, it is recommended that for a given classification the tests do not differ from those specified in this standard. If necessary, complementary requirements may be included in the relevant product standard. A guide for the details to be specified in relevant product standards is given in annex B.
For a particular type of equipment, a technical committee may specify different requirements provided that at least the same level of safety is ensured.
This standard deals only with enclosures that are in all other respects suitable for their intended use as specified in the relevant product standard and which from the point of view of materials and workmanship ensure that the claimed degrees of protection are maintained under the normal conditions of use.
This standard is also applicable to empty enclosures provided that the general test requirements are met and that the selected degree of protection is suitable for the type of equipment to be protected.
Measures to protect both the enclosure and the equipment inside the enclosure against external influences or conditions such as
- mechanical impacts
- corrosion
- corrosive solvents (for example, cutting liquids)
- fungus
- vermin
- solar radiation
- icing
- moisture (for example, produced by condensation)
- explosive atmospheres
and the protection against contact with hazardous moving parts external to the enclosure (such as fans), are matters for the relevant product standard to be protected.
Barriers external to the enclosure and not attached to it and obstacles which have been provided solely for the safety of personnel are not considered as a part of the enclosure and are not dealt with in this standard.
languageEnglish, French
titleCSA CAN/CSA-C22.2 NO. 60529:05num
titleEnglish -- Degrees of protection provided by enclosures (IP Code) - First Editionen
titleFrench -- Degrés de protection procurés par les enveloppes (Code IP) - First Editionother
typestandard
page114
statusActive
treeCSA - CSA Group:;2010
contenttypefulltext
DSpace software copyright © 2017-2020  DuraSpace
نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
yabeshDSpacePersian
 
DSpace software copyright © 2017-2020  DuraSpace
نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
yabeshDSpacePersian