IEEE 484

Recommended Practice for Installation Design and Installation of Vented Lead-Acid Batteries for Stationary Applications

Organization:
IEEE - The Institute of Electrical and Electronics Engineers, Inc.
Year: 2008

Abstract: This recommended practice provides recommended design practices and procedures for storage, location, mounting, ventilation, instrumentation, preassembly, assembly, and charging of vented lead-acid batteries. Required safety practices are also included. This recommended practice is applicable to full float stationary applications where a battery charger normally maintains the battery fully charged and provides the direct current (dc) loads. However, specific applications, such as emergency lighting units, semiportable equipment, and alternate energy applications, may have other appropriate practices that are beyond the scope of this recommended practice.
The portions of this recommended practice that specifically relate to personnel safety are mandatory instructions and are designated by the word shall; all other portions are recommended practices and are designated by the word should.
Sizing, maintenance, capacity testing, charging equipment, dry-charged cells, and consideration of other types of batteries are beyond the scope of this recommended practice.
Purpose
This recommended practice is meant to provide organizations with criteria to be used for storage, location, mounting, ventilation, instrumentation, preassembly, assembly, and charging of vented lead-acid batteries.
URI: https://yse.yabesh.ir/std/handle/yse/194333
Subject: ventilation
Collections :
  • IEEE - The Institute of Electrical and Electronics Engineers, Inc.
  • Download PDF : (423.2Kb)
  • Show Full MetaData Hide Full MetaData
  • Statistics

    IEEE 484

Show full item record

contributor authorIEEE - The Institute of Electrical and Electronics Engineers, Inc.
date accessioned2017-09-04T18:11:22Z
date available2017-09-04T18:11:22Z
date copyright09/12/2002 (R 2008)
date issued2008
identifier otherGZNRLCAAAAAAAAAA.pdf
identifier urihttps://yse.yabesh.ir/std/handle/yse/194333
description abstractThis recommended practice provides recommended design practices and procedures for storage, location, mounting, ventilation, instrumentation, preassembly, assembly, and charging of vented lead-acid batteries. Required safety practices are also included. This recommended practice is applicable to full float stationary applications where a battery charger normally maintains the battery fully charged and provides the direct current (dc) loads. However, specific applications, such as emergency lighting units, semiportable equipment, and alternate energy applications, may have other appropriate practices that are beyond the scope of this recommended practice.
The portions of this recommended practice that specifically relate to personnel safety are mandatory instructions and are designated by the word shall; all other portions are recommended practices and are designated by the word should.
Sizing, maintenance, capacity testing, charging equipment, dry-charged cells, and consideration of other types of batteries are beyond the scope of this recommended practice.
Purpose
This recommended practice is meant to provide organizations with criteria to be used for storage, location, mounting, ventilation, instrumentation, preassembly, assembly, and charging of vented lead-acid batteries.
languageEnglish
titleIEEE 484num
titleRecommended Practice for Installation Design and Installation of Vented Lead-Acid Batteries for Stationary Applicationsen
typestandard
page23
statusActive
treeIEEE - The Institute of Electrical and Electronics Engineers, Inc.:;2008
contenttypefulltext
subject keywordsventilation
DSpace software copyright © 2017-2020  DuraSpace
نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
yabeshDSpacePersian
 
DSpace software copyright © 2017-2020  DuraSpace
نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
yabeshDSpacePersian