UL SUBJECT 1276

UL Outline for Investigation Welding Cable - Issue 2

Organization:
UL - UL
Year: 2015

Abstract: This Outline covers single-conductor 8 AWG – 500 kcmil (8.37 mm2 – 253 mm2) welding cable intended for use in the secondary circuits of electric welders in accordance with Article 630 and other applicable parts of the National Electrical Code, ANSI/NFPA 70. The cable is rated for a temperature of 60, 75, 90, or 105°C at either 100 or 600 volts. The cable is rated 600 volts only when ²600 volts² or ²600 V² is marked on the tag and on the outer surface of the cable. Likewise, cable rated for 75, 90, or 105°C is both tag and surface marked ²75C², ²90C², or ²105C² as applicable
URI: https://yse.yabesh.ir/std/handle/yse/195168
Collections :
  • UL - UL
  • Download PDF : (28.46Kb)
  • Show Full MetaData Hide Full MetaData
  • Statistics

    UL SUBJECT 1276

Show full item record

contributor authorUL - UL
date accessioned2017-09-04T18:12:08Z
date available2017-09-04T18:12:08Z
date copyright2015.10.01
date issued2015
identifier otherHBSAMFAAAAAAAAAA.pdf
identifier urihttps://yse.yabesh.ir/std/handle/yse/195168
description abstractThis Outline covers single-conductor 8 AWG – 500 kcmil (8.37 mm2 – 253 mm2) welding cable intended for use in the secondary circuits of electric welders in accordance with Article 630 and other applicable parts of the National Electrical Code, ANSI/NFPA 70. The cable is rated for a temperature of 60, 75, 90, or 105°C at either 100 or 600 volts. The cable is rated 600 volts only when ²600 volts² or ²600 V² is marked on the tag and on the outer surface of the cable. Likewise, cable rated for 75, 90, or 105°C is both tag and surface marked ²75C², ²90C², or ²105C² as applicable
languageEnglish
titleUL SUBJECT 1276num
titleUL Outline for Investigation Welding Cable - Issue 2en
typestandard
page8
statusActive
treeUL - UL:;2015
contenttypefulltext