• 0
    • ارسال درخواست
    • حذف همه
    • Industrial Standards
    • Defence Standards
  • درباره ما
  • درخواست موردی
  • فهرست استانداردها
    • Industrial Standards
    • Defence Standards
  • راهنما
  • Login
  • لیست خرید شما 0
    • ارسال درخواست
    • حذف همه
View Item 
  •   YSE
  • Industrial Standards
  • IEEE - The Institute of Electrical and Electronics Engineers, Inc.
  • View Item
  •   YSE
  • Industrial Standards
  • IEEE - The Institute of Electrical and Electronics Engineers, Inc.
  • View Item
  • All Fields
  • Title(or Doc Num)
  • Organization
  • Year
  • Subject
Advanced Search
JavaScript is disabled for your browser. Some features of this site may not work without it.

Archive

IEEE C57.12.59

Guide for Dry-Type Transformer Through-Fault Current Duration

Organization:
IEEE - The Institute of Electrical and Electronics Engineers, Inc.
Year: 2006

Abstract: This guide applies to dry-type transformers designated as Category I and Category II in IEEE Std C57.12.01-1998.1 Category III transformers have not been included since these are not commonly manufactured and may require special consideration depending on the manufacturer’s recommendations.
Purpose
Protective devices, such as relays and fuses, have well-defined operating characteristics that relate fault magnitude to clearing time. It is desirable that these characteristic curves be coordinated with comparable curves applicable to dry-type transformers that relate duration and fault magnitude to withstand capability.
This guide sets forth recommendations believed essential for the application of overcurrent protective devices that limit the exposure time of dry-type transformers to short-circuit currents. This guide is not intended to imply overload capability.
URI: https://yse.yabesh.ir/std/handle/yse/195408
Collections :
  • IEEE - The Institute of Electrical and Electronics Engineers, Inc.
  • Download PDF : (105.9Kb)
  • Show Full MetaData Hide Full MetaData
  • Statistics

    IEEE C57.12.59

Show full item record

contributor authorIEEE - The Institute of Electrical and Electronics Engineers, Inc.
date accessioned2017-09-04T18:12:21Z
date available2017-09-04T18:12:21Z
date copyright12/06/2001 (R 2006)
date issued2006
identifier otherHCJZFCAAAAAAAAAA.pdf
identifier urihttps://yse.yabesh.ir/std/handle/yse/195408
description abstractThis guide applies to dry-type transformers designated as Category I and Category II in IEEE Std C57.12.01-1998.1 Category III transformers have not been included since these are not commonly manufactured and may require special consideration depending on the manufacturer’s recommendations.
Purpose
Protective devices, such as relays and fuses, have well-defined operating characteristics that relate fault magnitude to clearing time. It is desirable that these characteristic curves be coordinated with comparable curves applicable to dry-type transformers that relate duration and fault magnitude to withstand capability.
This guide sets forth recommendations believed essential for the application of overcurrent protective devices that limit the exposure time of dry-type transformers to short-circuit currents. This guide is not intended to imply overload capability.
languageEnglish
titleIEEE C57.12.59num
titleGuide for Dry-Type Transformer Through-Fault Current Durationen
typestandard
page13
statusActive
treeIEEE - The Institute of Electrical and Electronics Engineers, Inc.:;2006
contenttypefulltext
DSpace software copyright © 2017-2020  DuraSpace
نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
yabeshDSpacePersian
 
DSpace software copyright © 2017-2020  DuraSpace
نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
yabeshDSpacePersian