• 0
    • ارسال درخواست
    • حذف همه
    • Industrial Standards
    • Defence Standards
  • درباره ما
  • درخواست موردی
  • فهرست استانداردها
    • Industrial Standards
    • Defence Standards
  • راهنما
  • Login
  • لیست خرید شما 0
    • ارسال درخواست
    • حذف همه
View Item 
  •   YSE
  • Industrial Standards
  • ASHRAE - American Society of Heating, Refrigerating and Air-Conditioning Engineers, Inc.
  • View Item
  •   YSE
  • Industrial Standards
  • ASHRAE - American Society of Heating, Refrigerating and Air-Conditioning Engineers, Inc.
  • View Item
  • All Fields
  • Title(or Doc Num)
  • Organization
  • Year
  • Subject
Advanced Search
JavaScript is disabled for your browser. Some features of this site may not work without it.

Archive

ASHRAE AEDG

Advanced Energy Design Guide for Grocery Stores

Organization:
ASHRAE - American Society of Heating, Refrigerating and Air-Conditioning Engineers, Inc.
Year: 2015

Abstract: This Guide is intended for grocery stores ranging in size from 25,000 to 65,000 ft2 with medium- and low-temperature refrigerated cases and walk-ins, but it also applies to smaller or larger stores with similar space types. Space types covered by the Guide include dry goods, meat/dairy, produce, deli, bakery, restrooms, mechanical rooms, meeting/break rooms, offices, corridors, vestibules, and back-of-house storage, including receiving areas. This Guide does not cover parking garages, campus utilities such as chilled water and steam, water use, or sewage disposal.
The primary focus of this Guide is new construction, but recommendations may be equally applicable to stores undergoing complete renovation and in part to many other renovation, addition, remodeling, and modernization projects (including changes to one or more systems in existing buildings).
Included in the Guide are recommendations for the design of the following:
  • Building opaque envelope and fenestration
  • Lighting systems, including electrical interior and exterior lights and daylighting
  • Heating, ventilation, and air-conditioning (HVAC) systems
  • Building automation and controls
  • Outdoor air requirements
  •  Service water heating
  • Plug and process loads
  • Commercial kitchens, including cooking appliances and exhaust hoods
  • Commercial refrigeration systems, including refrigerated display cases, walk-ins, compressor systems, condensers, heat recovery systems, and related control systems
  • Quality assurance, including commissioning and measurement and verification

Additional savings recommendations not necessary for 50% savings are discussed in the "Additional Bonus Savings" section of Chapter 5.
The recommendation tables in Chapter 4 do not include all the components listed in ASHRAE/IESNA Standard 90.1-2004 (ASHRAE 2004). Though this Guide focuses only on the primary energy systems within a building, the underlying energy analysis assumes that all the other components and system comply with the minimum design criteria in ASHRAE/ IESNA Standard 90.1 (ASHRAE 2013a) and ASHRAE Standard 62.1, Ventilation for Acceptable Indoor Air Quality (ASHRAE 2013b).
In addition, this Guide is not intended to substitute for rating systems or references that address the full range of sustainability issues in food retail design, such as acoustics, productivity, sales rates, indoor air quality, water efficiency, landscaping, and transportation, except as they relate to energy use. Nor is it a comprehensive design text. The Guide assumes good design skills and expertise in grocery store design.
URI: https://yse.yabesh.ir/std/handle/yse/195717
Collections :
  • ASHRAE - American Society of Heating, Refrigerating and Air-Conditioning Engineers, Inc.
  • Download PDF : (10.00Mb)
  • Show Full MetaData Hide Full MetaData
  • Statistics

    ASHRAE AEDG

Show full item record

contributor authorASHRAE - American Society of Heating, Refrigerating and Air-Conditioning Engineers, Inc.
date accessioned2017-09-04T18:12:45Z
date available2017-09-04T18:12:45Z
date copyright2015.01.01
date issued2015
identifier otherHDDIKFAAAAAAAAAA.pdf
identifier urihttps://yse.yabesh.ir/std/handle/yse/195717
description abstractThis Guide is intended for grocery stores ranging in size from 25,000 to 65,000 ft2 with medium- and low-temperature refrigerated cases and walk-ins, but it also applies to smaller or larger stores with similar space types. Space types covered by the Guide include dry goods, meat/dairy, produce, deli, bakery, restrooms, mechanical rooms, meeting/break rooms, offices, corridors, vestibules, and back-of-house storage, including receiving areas. This Guide does not cover parking garages, campus utilities such as chilled water and steam, water use, or sewage disposal.
The primary focus of this Guide is new construction, but recommendations may be equally applicable to stores undergoing complete renovation and in part to many other renovation, addition, remodeling, and modernization projects (including changes to one or more systems in existing buildings).
Included in the Guide are recommendations for the design of the following:
  • Building opaque envelope and fenestration
  • Lighting systems, including electrical interior and exterior lights and daylighting
  • Heating, ventilation, and air-conditioning (HVAC) systems
  • Building automation and controls
  • Outdoor air requirements
  •  Service water heating
  • Plug and process loads
  • Commercial kitchens, including cooking appliances and exhaust hoods
  • Commercial refrigeration systems, including refrigerated display cases, walk-ins, compressor systems, condensers, heat recovery systems, and related control systems
  • Quality assurance, including commissioning and measurement and verification

Additional savings recommendations not necessary for 50% savings are discussed in the "Additional Bonus Savings" section of Chapter 5.
The recommendation tables in Chapter 4 do not include all the components listed in ASHRAE/IESNA Standard 90.1-2004 (ASHRAE 2004). Though this Guide focuses only on the primary energy systems within a building, the underlying energy analysis assumes that all the other components and system comply with the minimum design criteria in ASHRAE/ IESNA Standard 90.1 (ASHRAE 2013a) and ASHRAE Standard 62.1, Ventilation for Acceptable Indoor Air Quality (ASHRAE 2013b).
In addition, this Guide is not intended to substitute for rating systems or references that address the full range of sustainability issues in food retail design, such as acoustics, productivity, sales rates, indoor air quality, water efficiency, landscaping, and transportation, except as they relate to energy use. Nor is it a comprehensive design text. The Guide assumes good design skills and expertise in grocery store design.
languageEnglish
titleASHRAE AEDGnum
titleAdvanced Energy Design Guide for Grocery Storesen
typestandard
page254
statusActive
treeASHRAE - American Society of Heating, Refrigerating and Air-Conditioning Engineers, Inc.:;2015
contenttypefulltext
DSpace software copyright © 2017-2020  DuraSpace
نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
yabeshDSpacePersian
 
DSpace software copyright © 2017-2020  DuraSpace
نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
yabeshDSpacePersian