UL 1659 BULLETIN
UL Standard for Safety Attachment Plug Blades for Use in Cord Sets and Power-Supply Cords - COMMENTS DUE: October 12, 2009
Organization:
UL - UL
Year: 2009
Abstract: General
These requirements cover the blades of attachment plugs and current taps intended to be connected to the conductors of flexible cords using crimped connections, for use on cord sets and power-supply cords complying with the Standard for Cord Sets and Power-Supply Cords, UL 817, within the limits set forth in 1.2.1 for type of blades and 1.3.1 for size of conductors.
Type of blades
These requirements apply to blades, solid and folded, of attachment plugs and current taps rated 15 or 20 A, for general purpose use. These requirements do not apply to the grounding blade (pin) of grounding type attachment plugs or current taps.
Conductor sizes
These requirements apply to blades intended to be attached to 18 AWG (0.82 mm2) - 10 AWG (5.3 mm2) conductors.
These requirements cover the blades of attachment plugs and current taps intended to be connected to the conductors of flexible cords using crimped connections, for use on cord sets and power-supply cords complying with the Standard for Cord Sets and Power-Supply Cords, UL 817, within the limits set forth in 1.2.1 for type of blades and 1.3.1 for size of conductors.
Type of blades
These requirements apply to blades, solid and folded, of attachment plugs and current taps rated 15 or 20 A, for general purpose use. These requirements do not apply to the grounding blade (pin) of grounding type attachment plugs or current taps.
Conductor sizes
These requirements apply to blades intended to be attached to 18 AWG (0.82 mm2) - 10 AWG (5.3 mm2) conductors.
Collections
:
-
Statistics
UL 1659 BULLETIN
Show full item record
| contributor author | UL - UL | |
| date accessioned | 2017-09-04T18:15:23Z | |
| date available | 2017-09-04T18:15:23Z | |
| date copyright | 08/28/2009 | |
| date issued | 2009 | |
| identifier other | HKDCOCAAAAAAAAAA.pdf | |
| identifier uri | https://yse.yabesh.ir/std/handle/yse/198304 | |
| description abstract | General These requirements cover the blades of attachment plugs and current taps intended to be connected to the conductors of flexible cords using crimped connections, for use on cord sets and power-supply cords complying with the Standard for Cord Sets and Power-Supply Cords, UL 817, within the limits set forth in 1.2.1 for type of blades and 1.3.1 for size of conductors. Type of blades These requirements apply to blades, solid and folded, of attachment plugs and current taps rated 15 or 20 A, for general purpose use. These requirements do not apply to the grounding blade (pin) of grounding type attachment plugs or current taps. Conductor sizes These requirements apply to blades intended to be attached to 18 AWG (0.82 mm2) - 10 AWG (5.3 mm2) conductors. | |
| language | English | |
| title | UL 1659 BULLETIN | num |
| title | UL Standard for Safety Attachment Plug Blades for Use in Cord Sets and Power-Supply Cords - COMMENTS DUE: October 12, 2009 | en |
| type | standard | |
| page | 2 | |
| status | Active | |
| tree | UL - UL:;2009 | |
| contenttype | fulltext |

درباره ما