UL 817 BULLETIN

UL Standard for Safety Cord Sets and Power-Supply Cords - COMMENTS DUE: September 2, 2011

Organization:
UL - UL
Year: 2011

Abstract: These requirements cover power-supply cords for use as supply connections for appliances in accordance with the National Electrical Code.
These requirements also cover cord sets for use in extending a branch circuit supply to the power-supply cord of a portable appliance by means of flexible cord in accordance with the National Electrical Code.
When a specific section makes reference to a general section, and there is a conflict of requirements, the requirements of the specific section shall apply.
Unless otherwise noted, cord sets and power-supply cords shall be considered to be intended for indoor use.
Hospital Grade Attachment Plugs
The requirements in Sections 106 - 113 cover molded-on attachment plugs intended for hospital use in other than hazardous locations in accordance with Article 517 of the National Electrical Code, ANSI/NFPA 70. They are applicable only to nonlocking type devices of conventional configuration (Standard for Wiring Devices - Dimensional Requirements ANSI/NEMA WD 6) rated 15 or 20 A, 125 or 250 V. Attachment plugs shall be of the straight type (longitudinal axis of flexible cord parallel to that of the line blades), or right angle type (longitudinal axis of flexible cord at right angle to that of the line blades), molded onto flexible cord.
Other types such as locking-type configurations or devices for hazardous locations can be investigated based on the Hospital Grade test program in this standard along with any modifications needed to adequately represent the expected use of the device.
URI: https://yse.yabesh.ir/std/handle/yse/198445
Collections :
  • UL - UL
  • Download PDF : (24.03Kb)
  • Show Full MetaData Hide Full MetaData
  • Statistics

    UL 817 BULLETIN

Show full item record

contributor authorUL - UL
date accessioned2017-09-04T18:15:30Z
date available2017-09-04T18:15:30Z
date copyright08/18/2011
date issued2011
identifier otherHKNDNEAAAAAAAAAA.pdf
identifier urihttps://yse.yabesh.ir/std/handle/yse/198445
description abstractThese requirements cover power-supply cords for use as supply connections for appliances in accordance with the National Electrical Code.
These requirements also cover cord sets for use in extending a branch circuit supply to the power-supply cord of a portable appliance by means of flexible cord in accordance with the National Electrical Code.
When a specific section makes reference to a general section, and there is a conflict of requirements, the requirements of the specific section shall apply.
Unless otherwise noted, cord sets and power-supply cords shall be considered to be intended for indoor use.
Hospital Grade Attachment Plugs
The requirements in Sections 106 - 113 cover molded-on attachment plugs intended for hospital use in other than hazardous locations in accordance with Article 517 of the National Electrical Code, ANSI/NFPA 70. They are applicable only to nonlocking type devices of conventional configuration (Standard for Wiring Devices - Dimensional Requirements ANSI/NEMA WD 6) rated 15 or 20 A, 125 or 250 V. Attachment plugs shall be of the straight type (longitudinal axis of flexible cord parallel to that of the line blades), or right angle type (longitudinal axis of flexible cord at right angle to that of the line blades), molded onto flexible cord.
Other types such as locking-type configurations or devices for hazardous locations can be investigated based on the Hospital Grade test program in this standard along with any modifications needed to adequately represent the expected use of the device.
languageEnglish
titleUL 817 BULLETINnum
titleUL Standard for Safety Cord Sets and Power-Supply Cords - COMMENTS DUE: September 2, 2011en
typestandard
page4
statusActive
treeUL - UL:;2011
contenttypefulltext
DSpace software copyright © 2017-2020  DuraSpace
نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
yabeshDSpacePersian
 
DSpace software copyright © 2017-2020  DuraSpace
نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
yabeshDSpacePersian