ASHRAE LV-11-C005

Capacity Control of Air Coils for Heating and Cooling: Transfer Functions, Drive Power and System Design

Organization:
ASHRAE - American Society of Heating, Refrigerating and Air-Conditioning Engineers, Inc.
Year: 2011

Abstract: ABSTRACT
Liquid-to-air coils used as air heating system coils and air system cooling coils for air-conditioning, refrigeration etc. rarely use their design capacity. The capacity must therefore be reduced accordingly, traditionally by means of onoff operation or by means of control valves. Draw-backs of traditional control are excessive pressure drop and drive power to pumps due to high flows as well as the need for balancing valves and control valves with authority. There are, however, possibilities to substantially reduce the drive energy of pumps and fans for air coils, e.g. by replacing valve and damper control by direct control of decentralized pumps and fans. This may achieve better control at a lower cost while using substantially less drive energy.
This paper includes basic analysis of heat transfer and control methods to study how coil design affects the transfer function of an air coil on capacity turn-down. The analysis indicates that direct flow control, using variable-speed pumps, may require only a fraction of the drive power needed by traditional valve control. Furthermore, system designs for low flow rate and pressure drop also provide opportunities for new types of laminar-flow coil designs.
Results show that the transfer functions of alternative control methods for the capacity and outlet temperatures of air coils can be written as simple functions of the controlling variable (supply temperature, inlet temperature or coil liquid flow rate). The transfer functions may be tailored to specific needs by changing design parameters such as the design values of air and liquid flow rate and the heat transfer characteristics and heat transfer areas of the respective air and liquid sides. Also, the paper provides an example of alternative system design and control strategy.
URI: https://yse.yabesh.ir/std/handle/yse/200944
Collections :
  • ASHRAE - American Society of Heating, Refrigerating and Air-Conditioning Engineers, Inc.
  • Download PDF : (364.2Kb)
  • Show Full MetaData Hide Full MetaData
  • Statistics

    ASHRAE LV-11-C005

Show full item record

contributor authorASHRAE - American Society of Heating, Refrigerating and Air-Conditioning Engineers, Inc.
date accessioned2017-09-04T18:18:13Z
date available2017-09-04T18:18:13Z
date copyright01/01/2011
date issued2011
identifier otherHQXTKEAAAAAAAAAA.pdf
identifier urihttps://yse.yabesh.ir/std/handle/yse/200944
description abstractABSTRACT
Liquid-to-air coils used as air heating system coils and air system cooling coils for air-conditioning, refrigeration etc. rarely use their design capacity. The capacity must therefore be reduced accordingly, traditionally by means of onoff operation or by means of control valves. Draw-backs of traditional control are excessive pressure drop and drive power to pumps due to high flows as well as the need for balancing valves and control valves with authority. There are, however, possibilities to substantially reduce the drive energy of pumps and fans for air coils, e.g. by replacing valve and damper control by direct control of decentralized pumps and fans. This may achieve better control at a lower cost while using substantially less drive energy.
This paper includes basic analysis of heat transfer and control methods to study how coil design affects the transfer function of an air coil on capacity turn-down. The analysis indicates that direct flow control, using variable-speed pumps, may require only a fraction of the drive power needed by traditional valve control. Furthermore, system designs for low flow rate and pressure drop also provide opportunities for new types of laminar-flow coil designs.
Results show that the transfer functions of alternative control methods for the capacity and outlet temperatures of air coils can be written as simple functions of the controlling variable (supply temperature, inlet temperature or coil liquid flow rate). The transfer functions may be tailored to specific needs by changing design parameters such as the design values of air and liquid flow rate and the heat transfer characteristics and heat transfer areas of the respective air and liquid sides. Also, the paper provides an example of alternative system design and control strategy.
languageEnglish
titleASHRAE LV-11-C005num
titleCapacity Control of Air Coils for Heating and Cooling: Transfer Functions, Drive Power and System Designen
typestandard
page8
statusActive
treeASHRAE - American Society of Heating, Refrigerating and Air-Conditioning Engineers, Inc.:;2011
contenttypefulltext
DSpace software copyright © 2017-2020  DuraSpace
نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
yabeshDSpacePersian
 
DSpace software copyright © 2017-2020  DuraSpace
نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
yabeshDSpacePersian