Archive

ASHRAE LO-09-035

Building Heat Load Contributions from Medium and Low Voltage Switchgear—Part II: Component and Overall Switchgear Heat Gains

Organization:
ASHRAE - American Society of Heating, Refrigerating and Air-Conditioning Engineers, Inc.
Year: 2009

Abstract: ABSTRACT
Utility power sub-stations, industrial plants, and buildings use electrical power equipment in low voltage (LV) and medium voltage (MV) levels. A large number of electrical brands and products together with a lack of power efficiency information provide complications for HVAC engineers and designers in predicting power equipment heat loss. This is very true for LV and MV switchgear. Environmental heat gain information is very important for sizing HVAC equipment. The objectives of this paper are to update information on heat loss by LV and MV switchgear and to show these losses can be predicted. Two spreadsheet models are presented that calculate the power loss for low and medium voltage switchgear and practical examples are shown for each case using realistic information. The spreadsheets provide an approximation of the dissipated power losses if actual current loadings are used. However, if breaker and bus amp ratings (unknown loading case) are used in place of the actual loadings, the dissipated power loss of the LV and MV switchgear will be overestimated. This emphasizes the need of using the actual loadings for each bus and circuit breaker to obtain realistic results.
URI: https://yse.yabesh.ir/std/handle/yse/201358
Collections :
  • ASHRAE - American Society of Heating, Refrigerating and Air-Conditioning Engineers, Inc.
  • Download PDF : (1.262Mb)
  • Show Full MetaData Hide Full MetaData
  • Statistics

    ASHRAE LO-09-035

Show full item record

contributor authorASHRAE - American Society of Heating, Refrigerating and Air-Conditioning Engineers, Inc.
date accessioned2017-09-04T18:18:34Z
date available2017-09-04T18:18:34Z
date copyright01/01/2009
date issued2009
identifier otherHRYXPCAAAAAAAAAA.pdf
identifier urihttps://yse.yabesh.ir/std/handle/yse/201358
description abstractABSTRACT
Utility power sub-stations, industrial plants, and buildings use electrical power equipment in low voltage (LV) and medium voltage (MV) levels. A large number of electrical brands and products together with a lack of power efficiency information provide complications for HVAC engineers and designers in predicting power equipment heat loss. This is very true for LV and MV switchgear. Environmental heat gain information is very important for sizing HVAC equipment. The objectives of this paper are to update information on heat loss by LV and MV switchgear and to show these losses can be predicted. Two spreadsheet models are presented that calculate the power loss for low and medium voltage switchgear and practical examples are shown for each case using realistic information. The spreadsheets provide an approximation of the dissipated power losses if actual current loadings are used. However, if breaker and bus amp ratings (unknown loading case) are used in place of the actual loadings, the dissipated power loss of the LV and MV switchgear will be overestimated. This emphasizes the need of using the actual loadings for each bus and circuit breaker to obtain realistic results.
languageEnglish
titleASHRAE LO-09-035num
titleBuilding Heat Load Contributions from Medium and Low Voltage Switchgear—Part II: Component and Overall Switchgear Heat Gainsen
typestandard
page13
statusActive
treeASHRAE - American Society of Heating, Refrigerating and Air-Conditioning Engineers, Inc.:;2009
contenttypefulltext