IEEE 1427

Guide for Recommended Electrical Clearances and Insulation Levels in Air-Insulated Electrical Power Substations

Organization:
IEEE - The Institute of Electrical and Electronics Engineers, Inc.
Year: 2006

Abstract: This guide, covering three-phase ac systems from 1 kV to 800 kV, provides recommended electrical operating and safety clearances and insulation levels in air-insulated electric supply substations; addresses insulation coordination procedures; provides design procedures for the selection and coordination of the insulation levels within the station as they relate to substation clearances; and addresses how reduced clearances in high-voltage ac substations will allow for compact bus arrangements and substation voltage uprating applications.
This guide addresses insulation coordination procedures, including the choice of insulation levels and arrester specification, in limited detail and only as relevant to clearance requirements. Detailed and expanded coverage of insulation coordination procedures is provided in other ANSI and IEEE guides and standards (see Clause 2).
This guide focuses on open-air bus assemblies and configurations and excludes apparatus clearances (i.e., bushing clearances for transformers, and breakers). Detailed coverage of apparatus clearances is provided in other applicable guides and standards.
Purpose
Proper electrical clearances are necessary for the design, construction, and operation of electric supply substations. This document develops guidelines for the application of recommended electrical clearances and insulation levels in air-insulated substations. The recommended clearances incorporate both design/operating clearances and safety clearances.
URI: https://yse.yabesh.ir/std/handle/yse/201884
Subject: basic lightning impulse insulation level (BIL)
Collections :
  • IEEE - The Institute of Electrical and Electronics Engineers, Inc.
  • Download PDF : (604.2Kb)
  • Show Full MetaData Hide Full MetaData
  • Statistics

    IEEE 1427

Show full item record

contributor authorIEEE - The Institute of Electrical and Electronics Engineers, Inc.
date accessioned2017-09-04T18:19:10Z
date available2017-09-04T18:19:10Z
date copyright39057
date issued2006
identifier otherAFYQACAAAAAAAAAA.pdf
identifier urihttps://yse.yabesh.ir/std/handle/yse/201884
description abstractThis guide, covering three-phase ac systems from 1 kV to 800 kV, provides recommended electrical operating and safety clearances and insulation levels in air-insulated electric supply substations; addresses insulation coordination procedures; provides design procedures for the selection and coordination of the insulation levels within the station as they relate to substation clearances; and addresses how reduced clearances in high-voltage ac substations will allow for compact bus arrangements and substation voltage uprating applications.
This guide addresses insulation coordination procedures, including the choice of insulation levels and arrester specification, in limited detail and only as relevant to clearance requirements. Detailed and expanded coverage of insulation coordination procedures is provided in other ANSI and IEEE guides and standards (see Clause 2).
This guide focuses on open-air bus assemblies and configurations and excludes apparatus clearances (i.e., bushing clearances for transformers, and breakers). Detailed coverage of apparatus clearances is provided in other applicable guides and standards.
Purpose
Proper electrical clearances are necessary for the design, construction, and operation of electric supply substations. This document develops guidelines for the application of recommended electrical clearances and insulation levels in air-insulated substations. The recommended clearances incorporate both design/operating clearances and safety clearances.
languageEnglish
titleIEEE 1427num
titleGuide for Recommended Electrical Clearances and Insulation Levels in Air-Insulated Electrical Power Substationsen
typestandard
page50
statusActive
treeIEEE - The Institute of Electrical and Electronics Engineers, Inc.:;2006
contenttypefulltext
subject keywordsbasic lightning impulse insulation level (BIL)
subject keywordsbasic switching impulse insulation level (BSL)
subject keywordsclearances
subject keywordsinsulation coordination
subject keywordsinsulation levels
subject keywordssubstation