ASHRAE OR-16-C034

Is the Wheeler-Jonas Equation Applicable to Describe the Breakthrough Curve of an Oxidizing Gas: Ozone?

Organization:
ASHRAE - American Society of Heating, Refrigerating and Air-Conditioning Engineers, Inc.
Year: 2016

Abstract: Ozone is the criteria pollutant with respect to oxidizing gases to be tested in ASHRAE Standard 145.2-2011. In non-industrial buildings, ozone is normally removed by activated carbon (AC). In practice, how often the filters should be replaced is a key question. The Wheeler-Jonas equation (WJE) is widely used for describing breakthrough curves of organic vapours removal by AC. Some studies reported the WJE is also applicable of some inorganic gases including the acid gas - chlorine and the basic gas - ammonia.
This paper firstly investigated applicability of the WJE of an oxidizing gas - ozone. The experiments were conducted on a well-designed bench-scale test rig. The results indicated that the WJE does not work for ozone. There are two assumptions associating with the WJE, constant adsorption kinetics and neglecting axial diffusion. Multiple ozone-AC reaction mechanisms combined with different reactivities were confirmed from the literature review, which indicate the assumed constant adsorption kinetics is improper for ozone-AC reacitons.
Finally, a new mass balance model described by a partial differential equation (PDE) which introduces the axial diffusion term and first order kinetics accompanied by exponential deactivation was proposed. The PDE solution is in good agreement with the experimental data. The Péclet number was calculated with the estimated axial diffusion coefficient from the PDE model. The large value indicates the axial diffusion is not significant. Therefore, the constant adsorption kinetics assumed in the WJE is considered to be the major reason of its inapplicability of ozone.
URI: https://yse.yabesh.ir/std/handle/yse/202491
Collections :
  • ASHRAE - American Society of Heating, Refrigerating and Air-Conditioning Engineers, Inc.
  • Download PDF : (402.6Kb)
  • Show Full MetaData Hide Full MetaData
  • Statistics

    ASHRAE OR-16-C034

Show full item record

contributor authorASHRAE - American Society of Heating, Refrigerating and Air-Conditioning Engineers, Inc.
date accessioned2017-09-04T18:19:50Z
date available2017-09-04T18:19:50Z
date copyright2016.01.01
date issued2016
identifier otherHUXPOFAAAAAAAAAA.pdf
identifier urihttps://yse.yabesh.ir/std/handle/yse/202491
description abstractOzone is the criteria pollutant with respect to oxidizing gases to be tested in ASHRAE Standard 145.2-2011. In non-industrial buildings, ozone is normally removed by activated carbon (AC). In practice, how often the filters should be replaced is a key question. The Wheeler-Jonas equation (WJE) is widely used for describing breakthrough curves of organic vapours removal by AC. Some studies reported the WJE is also applicable of some inorganic gases including the acid gas - chlorine and the basic gas - ammonia.
This paper firstly investigated applicability of the WJE of an oxidizing gas - ozone. The experiments were conducted on a well-designed bench-scale test rig. The results indicated that the WJE does not work for ozone. There are two assumptions associating with the WJE, constant adsorption kinetics and neglecting axial diffusion. Multiple ozone-AC reaction mechanisms combined with different reactivities were confirmed from the literature review, which indicate the assumed constant adsorption kinetics is improper for ozone-AC reacitons.
Finally, a new mass balance model described by a partial differential equation (PDE) which introduces the axial diffusion term and first order kinetics accompanied by exponential deactivation was proposed. The PDE solution is in good agreement with the experimental data. The Péclet number was calculated with the estimated axial diffusion coefficient from the PDE model. The large value indicates the axial diffusion is not significant. Therefore, the constant adsorption kinetics assumed in the WJE is considered to be the major reason of its inapplicability of ozone.
languageEnglish
titleASHRAE OR-16-C034num
titleIs the Wheeler-Jonas Equation Applicable to Describe the Breakthrough Curve of an Oxidizing Gas: Ozone?en
typestandard
page8
statusActive
treeASHRAE - American Society of Heating, Refrigerating and Air-Conditioning Engineers, Inc.:;2016
contenttypefulltext
DSpace software copyright © 2017-2020  DuraSpace
نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
yabeshDSpacePersian
 
DSpace software copyright © 2017-2020  DuraSpace
نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
yabeshDSpacePersian