ASHRAE LV-11-C062

Demand Control Ventilation: Lessons from the Field- How to Avoid Common Problems

Organization:
ASHRAE - American Society of Heating, Refrigerating and Air-Conditioning Engineers, Inc.
Year: 2011

Abstract: Abstract
Demand control ventilation (DCV) has the potential to save energy by reducing ventilation rates in accordance with occupancy levels provided by the surrogate indication of CO2 levels. However, improperly installed, designed, or operated systems may save energy at the expense of Indoor Air Quality (IAQ) or enhance IAQ at the expense of energy. These outcomes may have the potential to foul the image of an otherwise viable energy efficiency measure. This paper reports what the authors believe to be common problems in the design, installation and operation of DCV systems which use CO2 as a surrogate for occupancy levels.
Six HVAC systems were investigated: two commercial offices, two medical offices, and two school environments. The design drawings, air balance reports, and current equipment set up were investigated. Four systems were controlled locally through roof top unit control logic and two systems were controlled by central building energy management systems. Functional testing of equipment was carried out and system parameters were logged including CO2 levels, fans states, and air stream temperatures. Functional testing was broken up into three system aspects. First, CO2 control signal functional testing was conducted to confirm that the control link between CO2 sensors and outside air damper positioning was in place. Second, sensor placement functional testing was conducted to confirm that the sensors placement could accurately report the CO2 levels of the controlled zone. Third, the Outside Air (OSA) level test was conducted by inspecting the air balance reports to determine the OSA rates and to confirm that the system was balanced in accordance with DCV standards.
The study found that no systems were functioning properly for a number of reasons, some of which were overlapping. Reasons for non-functionality included poor sensor placement, improper information provided in mechanical schedules or design documents, fan cycling issues, and poor installation. Details on failure modes will be presented. Proper engineering documentation requirements will be explained. Test, Adjust, Balance (TAB) specifications and DCV specific requirements for TAB along with information that building operators need to know about system operation will be presented.
URI: https://yse.yabesh.ir/std/handle/yse/203196
Collections :
  • ASHRAE - American Society of Heating, Refrigerating and Air-Conditioning Engineers, Inc.
  • Download PDF : (931.5Kb)
  • Show Full MetaData Hide Full MetaData
  • Statistics

    ASHRAE LV-11-C062

Show full item record

contributor authorASHRAE - American Society of Heating, Refrigerating and Air-Conditioning Engineers, Inc.
date accessioned2017-09-04T18:20:38Z
date available2017-09-04T18:20:38Z
date copyright01/01/2011
date issued2011
identifier otherHWXTKEAAAAAAAAAA.pdf
identifier urihttps://yse.yabesh.ir/std/handle/yse/203196
description abstractAbstract
Demand control ventilation (DCV) has the potential to save energy by reducing ventilation rates in accordance with occupancy levels provided by the surrogate indication of CO2 levels. However, improperly installed, designed, or operated systems may save energy at the expense of Indoor Air Quality (IAQ) or enhance IAQ at the expense of energy. These outcomes may have the potential to foul the image of an otherwise viable energy efficiency measure. This paper reports what the authors believe to be common problems in the design, installation and operation of DCV systems which use CO2 as a surrogate for occupancy levels.
Six HVAC systems were investigated: two commercial offices, two medical offices, and two school environments. The design drawings, air balance reports, and current equipment set up were investigated. Four systems were controlled locally through roof top unit control logic and two systems were controlled by central building energy management systems. Functional testing of equipment was carried out and system parameters were logged including CO2 levels, fans states, and air stream temperatures. Functional testing was broken up into three system aspects. First, CO2 control signal functional testing was conducted to confirm that the control link between CO2 sensors and outside air damper positioning was in place. Second, sensor placement functional testing was conducted to confirm that the sensors placement could accurately report the CO2 levels of the controlled zone. Third, the Outside Air (OSA) level test was conducted by inspecting the air balance reports to determine the OSA rates and to confirm that the system was balanced in accordance with DCV standards.
The study found that no systems were functioning properly for a number of reasons, some of which were overlapping. Reasons for non-functionality included poor sensor placement, improper information provided in mechanical schedules or design documents, fan cycling issues, and poor installation. Details on failure modes will be presented. Proper engineering documentation requirements will be explained. Test, Adjust, Balance (TAB) specifications and DCV specific requirements for TAB along with information that building operators need to know about system operation will be presented.
languageEnglish
titleASHRAE LV-11-C062num
titleDemand Control Ventilation: Lessons from the Field- How to Avoid Common Problemsen
typestandard
page7
statusActive
treeASHRAE - American Society of Heating, Refrigerating and Air-Conditioning Engineers, Inc.:;2011
contenttypefulltext
DSpace software copyright © 2017-2020  DuraSpace
نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
yabeshDSpacePersian
 
DSpace software copyright © 2017-2020  DuraSpace
نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
yabeshDSpacePersian