UL 486E

UL Standard for Safety Equipment Wiring Terminals for Use with Aluminum and/or Copper Conductors - Fifth Edition

Organization:
UL - UL
Year: 2015

Abstract: This Standard applies to equipment wiring terminals for use with all alloys of copper, aluminum, or copper-clad aluminum conductors, in accordance with the National Electrical Code, ANSI/NFPA 70, as follows:
a) equipment wiring terminals intended to hold one or more conductor(s);
b) equipment wiring terminals intended for use in appliances and equipment that comply with the requirements for such appliances and equipment;
c) ampere-rated equipment wiring terminals;
d) horsepower rated equipment wiring terminals; and
e) wire range rated equipment wiring terminals.
These requirements apply to field wired equipment wiring terminals which are an integral part of the equipment, or are intended for use in specific equipment.
This Standard is intended for equipment wiring terminals suitable for use with conductors in the size ranges as follows:
a) Aluminum
1) 12 AWG (3.3 mm2) and 10 AWG (5.3 mm2) solid; and
2) 12 AWG (3.3 mm2) to 2 000 kcmil (1 010 mm2) stranded, Class B concentric, compressed, and compact.
b) Copper-Clad Aluminum
1) 12 AWG (3.3 mm2) and 10 AWG (5.3 mm2) solid; and
2) 12 AWG (3.3 mm2) to 2 000 kcmil (1 010 mm2) stranded, Class B concentric.
c) Copper
1) 30 AWG (0.05 mm2) to 10 AWG (5.3 mm2) solid; and
2) 30 AWG (0.05 mm2) to 2 000 kcmil (1 010 mm2) stranded, Class B concentric and compressed, and Class C concentric.
d) Compact-stranded copper conductors for 2 AWG (33.6 mm2) and larger.
e) Rigid (solid and stranded) metric wire falling within the ranges of the above AWG sizes.
Note: For example, an equipment wiring terminal rated for 6 AWG – 250 kcmil may be additionally rated for 16 – 120 mm2.
f) Other class and strand configurations as indicated by marking.
This Standard is intended for equipment wiring terminals suitable for currents not exceeding the ampacity of insulated conductors rated 75°C or 90°C in accordance with the rating of the equipment wiring terminal, if provided.
This Standard does not apply to:
a) insulated equipment wiring terminals; and
b) wire binding screw terminals.
URI: https://yse.yabesh.ir/std/handle/yse/205332
Collections :
  • UL - UL
  • Download PDF : (770.1Kb)
  • Show Full MetaData Hide Full MetaData
  • Statistics

    UL 486E

Show full item record

contributor authorUL - UL
date accessioned2017-09-04T18:22:55Z
date available2017-09-04T18:22:55Z
date copyright2015.09.30
date issued2015
identifier otherICSAMFAAAAAAAAAA.pdf
identifier urihttps://yse.yabesh.ir/std/handle/yse/205332
description abstractThis Standard applies to equipment wiring terminals for use with all alloys of copper, aluminum, or copper-clad aluminum conductors, in accordance with the National Electrical Code, ANSI/NFPA 70, as follows:
a) equipment wiring terminals intended to hold one or more conductor(s);
b) equipment wiring terminals intended for use in appliances and equipment that comply with the requirements for such appliances and equipment;
c) ampere-rated equipment wiring terminals;
d) horsepower rated equipment wiring terminals; and
e) wire range rated equipment wiring terminals.
These requirements apply to field wired equipment wiring terminals which are an integral part of the equipment, or are intended for use in specific equipment.
This Standard is intended for equipment wiring terminals suitable for use with conductors in the size ranges as follows:
a) Aluminum
1) 12 AWG (3.3 mm2) and 10 AWG (5.3 mm2) solid; and
2) 12 AWG (3.3 mm2) to 2 000 kcmil (1 010 mm2) stranded, Class B concentric, compressed, and compact.
b) Copper-Clad Aluminum
1) 12 AWG (3.3 mm2) and 10 AWG (5.3 mm2) solid; and
2) 12 AWG (3.3 mm2) to 2 000 kcmil (1 010 mm2) stranded, Class B concentric.
c) Copper
1) 30 AWG (0.05 mm2) to 10 AWG (5.3 mm2) solid; and
2) 30 AWG (0.05 mm2) to 2 000 kcmil (1 010 mm2) stranded, Class B concentric and compressed, and Class C concentric.
d) Compact-stranded copper conductors for 2 AWG (33.6 mm2) and larger.
e) Rigid (solid and stranded) metric wire falling within the ranges of the above AWG sizes.
Note: For example, an equipment wiring terminal rated for 6 AWG – 250 kcmil may be additionally rated for 16 – 120 mm2.
f) Other class and strand configurations as indicated by marking.
This Standard is intended for equipment wiring terminals suitable for currents not exceeding the ampacity of insulated conductors rated 75°C or 90°C in accordance with the rating of the equipment wiring terminal, if provided.
This Standard does not apply to:
a) insulated equipment wiring terminals; and
b) wire binding screw terminals.
languageEnglish
titleUL 486Enum
titleUL Standard for Safety Equipment Wiring Terminals for Use with Aluminum and/or Copper Conductors - Fifth Editionen
typestandard
page58
statusActive
treeUL - UL:;2015
contenttypefulltext
DSpace software copyright © 2017-2020  DuraSpace
نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
yabeshDSpacePersian
 
DSpace software copyright © 2017-2020  DuraSpace
نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
yabeshDSpacePersian