UL 1977 BULLETIN

UL Standard for Safety Component Connectors for Use in Data, Signal, Control and Power Applications - COMMENTS DUE: September 13, 2010

Organization:
UL - UL
Year: 2010

Abstract: These requirements cover single and multipole connectors, intended for factory assembly to copper or copper alloy conductors or printed wiring boards, for use in data, signal, control and power applications within and between electrical equipment.
These requirements apply to devices categorized as follows (See Figure 1.1 ):
a) Type 0 rated less than 8.3 A and less than 30 V rms (42 V peak);
b) Type 1A rated less than 8.3 A and from 30 V up to and including 600 V ac or dc, or both;
c) Type 1B rated from 8.3 A up to and including 200 A, and less than 30 V rms (42 V peak);
d) Type 2 rated from 8.3 A to less than 31 A and from 30 V up to and including 600 V ac or dc or both;
e) Type 3 rated from 31 A up to and including 200 A and from 30 V up to and including 600 V ac or dc, or both.
f) Type 4 rated from greater than 200 A up to and including 1000 A, and up to and including 600 V ac or dc.
Type designations used in this Standard only serve as a guide to determine appropriate requirements, and do not represent an assigned rating. A device not assigned a current rating is considered either to be Type 0 or Type 1A depending upon the assigned voltage rating.
This standard does not directly apply to the following but may supplement other applicable standards:
a) Devices produced integrally with flexible cord or cable that are covered by the Standard for Cord Sets and Power-Supply Cords, UL 817;
b) Devices intended for connection to the branch circuit, such as attachment plugs, cord connectors, receptacles, inlets, and outlets, that are covered by the Standard for Attachment Plugs and Receptacles, UL 498;
c) Devices solely intended for direct connection to the branch circuit in accordance with the National Electrical Code, NFPA 70, and that are provided with contacts of the pin and sleeve type, covered by the requirements for plugs, receptacles, and cable connectors of the pin and sleeve type, UL 1682;
d) Devices consisting of wiring terminals and supporting blocks intended for the connection of wiring that are covered by the Standard for Terminal Blocks, UL 1059;
e) Devices intended for use with telecommunications networks, that are covered by the Standard for Telephone Equipment, UL 1459, or the Standard for Communications Circuit Accessories, UL 1863;
f) Devices such as wire connectors and soldering lugs that are covered by the Standards for Wire Connectors – For Use With Copper Conductors, UL 486A; Splicing Wire Connectors, UL 486C; or Equipment Wiring Terminals, UL 486E;
g) Devices such as quick-connect terminals that are covered by the Standard for Quick Connect Terminals, UL 310.
URI: https://yse.yabesh.ir/std/handle/yse/205699
Collections :
  • UL - UL
  • Download PDF : (21.87Kb)
  • Show Full MetaData Hide Full MetaData
  • Statistics

    UL 1977 BULLETIN

Show full item record

contributor authorUL - UL
date accessioned2017-09-04T18:23:15Z
date available2017-09-04T18:23:15Z
date copyright08/12/2010
date issued2010
identifier otherIDRBVCAAAAAAAAAA.pdf
identifier urihttps://yse.yabesh.ir/std/handle/yse/205699
description abstractThese requirements cover single and multipole connectors, intended for factory assembly to copper or copper alloy conductors or printed wiring boards, for use in data, signal, control and power applications within and between electrical equipment.
These requirements apply to devices categorized as follows (See Figure 1.1 ):
a) Type 0 rated less than 8.3 A and less than 30 V rms (42 V peak);
b) Type 1A rated less than 8.3 A and from 30 V up to and including 600 V ac or dc, or both;
c) Type 1B rated from 8.3 A up to and including 200 A, and less than 30 V rms (42 V peak);
d) Type 2 rated from 8.3 A to less than 31 A and from 30 V up to and including 600 V ac or dc or both;
e) Type 3 rated from 31 A up to and including 200 A and from 30 V up to and including 600 V ac or dc, or both.
f) Type 4 rated from greater than 200 A up to and including 1000 A, and up to and including 600 V ac or dc.
Type designations used in this Standard only serve as a guide to determine appropriate requirements, and do not represent an assigned rating. A device not assigned a current rating is considered either to be Type 0 or Type 1A depending upon the assigned voltage rating.
This standard does not directly apply to the following but may supplement other applicable standards:
a) Devices produced integrally with flexible cord or cable that are covered by the Standard for Cord Sets and Power-Supply Cords, UL 817;
b) Devices intended for connection to the branch circuit, such as attachment plugs, cord connectors, receptacles, inlets, and outlets, that are covered by the Standard for Attachment Plugs and Receptacles, UL 498;
c) Devices solely intended for direct connection to the branch circuit in accordance with the National Electrical Code, NFPA 70, and that are provided with contacts of the pin and sleeve type, covered by the requirements for plugs, receptacles, and cable connectors of the pin and sleeve type, UL 1682;
d) Devices consisting of wiring terminals and supporting blocks intended for the connection of wiring that are covered by the Standard for Terminal Blocks, UL 1059;
e) Devices intended for use with telecommunications networks, that are covered by the Standard for Telephone Equipment, UL 1459, or the Standard for Communications Circuit Accessories, UL 1863;
f) Devices such as wire connectors and soldering lugs that are covered by the Standards for Wire Connectors – For Use With Copper Conductors, UL 486A; Splicing Wire Connectors, UL 486C; or Equipment Wiring Terminals, UL 486E;
g) Devices such as quick-connect terminals that are covered by the Standard for Quick Connect Terminals, UL 310.
languageEnglish
titleUL 1977 BULLETINnum
titleUL Standard for Safety Component Connectors for Use in Data, Signal, Control and Power Applications - COMMENTS DUE: September 13, 2010en
typestandard
page4
statusActive
treeUL - UL:;2010
contenttypefulltext
DSpace software copyright © 2017-2020  DuraSpace
نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
yabeshDSpacePersian
 
DSpace software copyright © 2017-2020  DuraSpace
نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
yabeshDSpacePersian