Show simple item record

TP-109 LOOP INDUCTANCE MEASUREMENT TEST PROCEDURE FOR ELECTRICAL CONNECTORS (1 nH – 10 nH)

contributor authorECIA - Electronic Components Industry Association
date accessioned2017-09-04T18:24:58Z
date available2017-09-04T18:24:58Z
date copyright05/20/2003 (R 2009)
date issued2009
identifier otherIHWLPCAAAAAAAAAA.pdf
identifier urihttps://yse.yabesh.ir/std/handle/yse/207250
description abstractThis procedure applies to interconnect assemblies, such as electrical connectors and sockets.
Object
This standard describes a test method to measure the loop inductance (1 nH – 10 nH range) in the frequency domain using probes and vector network analyzer.
NOTE — This test method is written for test professionals who are knowledgeable in the electronics field and are trained to use the referenced equipment. Because the measurement values are heavily influenced by the fixture and equipment this method cannot describe all of the possible combinations. The major equipment manufacturers provide Application Notes for more in-depth technical description of how to optimize the use of their equipment. It is imperative that the referencing document include the necessary description and sketches for the test professional to understand how to setup and perform the requested measurements.
languageEnglish
titleECA EIA-364-109num
titleTP-109 LOOP INDUCTANCE MEASUREMENT TEST PROCEDURE FOR ELECTRICAL CONNECTORS (1 nH – 10 nH)en
typestandard
page40
statusActive
treeECIA - Electronic Components Industry Association:;2009
contenttypefulltext