• 0
    • ارسال درخواست
    • حذف همه
    • Industrial Standards
    • Defence Standards
  • درباره ما
  • درخواست موردی
  • فهرست استانداردها
    • Industrial Standards
    • Defence Standards
  • راهنما
  • Login
  • لیست خرید شما 0
    • ارسال درخواست
    • حذف همه
View Item 
  •   YSE
  • Industrial Standards
  • IEEE - The Institute of Electrical and Electronics Engineers, Inc.
  • View Item
  •   YSE
  • Industrial Standards
  • IEEE - The Institute of Electrical and Electronics Engineers, Inc.
  • View Item
  • All Fields
  • Title(or Doc Num)
  • Organization
  • Year
  • Subject
Advanced Search
JavaScript is disabled for your browser. Some features of this site may not work without it.

Archive

IEEE 1450.2

IEEE Standard for Extensions to Standard Test Interface Language (STIL) (IEEE Std 1450 -1999) for DC Level Specification - IEEE Computer Society

Organization:
IEEE - The Institute of Electrical and Electronics Engineers, Inc.
Year: 2002

Abstract: FOREWORD
Standard Test Interface Language (STIL) (IEEE Std 1450-1999) was developed and approved with an intentionally constrained scope. While DC levels were explicitly excluded from that scope, it was apparent that DC levels were an area of interest and importance to the STIL user community. The P1450.2 Working Group was formed to address the extension of DC levels to the STIL standard.
Three main topics were identified as priorities for the work. These include per-pin reference levels for signal pins (e.g., VIH, VIL, VOH, VOL), device power supply levels (voltage and current), and power sequencing to the device under test. During the course of development, two other important topics were addressed. These included the capability for switching levels within a period, and for switching levels between vectors in a pattern.
Scope 
This standard defines the following:
a) Defines structures in STIL for specifying the DC conditions for a DUT. Examples of the DC conditions for device power supplies are DPS setup, power sequencing to the device, and power supply limiting/clamping. Examples of the DC conditions for commonly used signal references are VIL, VIH, VOL, VOH, IOL, IOH, VREF, VClampLow, and VClampHi.
b) Defines structures in STIL such that the DC conditions may be specified either globally, by pattern burst, by pattern, or by vector.
c) Defines structures in STIL to allow specification of alternate DC levels. Examples of commonly used alternate levels are VIHH, VIPP, and VILL.
d) Defines structures in STIL such that the DC levels and alternate levels can be selected within a period, much the same as timed format events
URI: https://yse.yabesh.ir/std/handle/yse/213765
Collections :
  • IEEE - The Institute of Electrical and Electronics Engineers, Inc.
  • Download PDF : (426.4Kb)
  • Show Full MetaData Hide Full MetaData
  • Statistics

    IEEE 1450.2

Show full item record

contributor authorIEEE - The Institute of Electrical and Electronics Engineers, Inc.
date accessioned2017-09-04T18:31:31Z
date available2017-09-04T18:31:31Z
date copyright37572
date issued2002
identifier otherIZBPCBAAAAAAAAAA.pdf
identifier urihttps://yse.yabesh.ir/std/handle/yse/213765
description abstractFOREWORD
Standard Test Interface Language (STIL) (IEEE Std 1450-1999) was developed and approved with an intentionally constrained scope. While DC levels were explicitly excluded from that scope, it was apparent that DC levels were an area of interest and importance to the STIL user community. The P1450.2 Working Group was formed to address the extension of DC levels to the STIL standard.
Three main topics were identified as priorities for the work. These include per-pin reference levels for signal pins (e.g., VIH, VIL, VOH, VOL), device power supply levels (voltage and current), and power sequencing to the device under test. During the course of development, two other important topics were addressed. These included the capability for switching levels within a period, and for switching levels between vectors in a pattern.
Scope 
This standard defines the following:
a) Defines structures in STIL for specifying the DC conditions for a DUT. Examples of the DC conditions for device power supplies are DPS setup, power sequencing to the device, and power supply limiting/clamping. Examples of the DC conditions for commonly used signal references are VIL, VIH, VOL, VOH, IOL, IOH, VREF, VClampLow, and VClampHi.
b) Defines structures in STIL such that the DC conditions may be specified either globally, by pattern burst, by pattern, or by vector.
c) Defines structures in STIL to allow specification of alternate DC levels. Examples of commonly used alternate levels are VIHH, VIPP, and VILL.
d) Defines structures in STIL such that the DC levels and alternate levels can be selected within a period, much the same as timed format events
languageEnglish
titleIEEE 1450.2num
titleIEEE Standard for Extensions to Standard Test Interface Language (STIL) (IEEE Std 1450 -1999) for DC Level Specification - IEEE Computer Societyen
typestandard
page44
statusActive
treeIEEE - The Institute of Electrical and Electronics Engineers, Inc.:;2002
contenttypefulltext
DSpace software copyright © 2017-2020  DuraSpace
نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
yabeshDSpacePersian
 
DSpace software copyright © 2017-2020  DuraSpace
نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
yabeshDSpacePersian