Archive

NASA-LLIS-0526

Lessons Learned – Magnetic Field Distribution in the Magneto-Optic Imaging Instrument

Organization:
NASA - National Aeronautics and Space Administration (NASA)
Year: 1994

Abstract: Description of Driving Event:
One of the most important elements for the further improvement of the performance of the magnetooptic imaging instrument is to quantify the contribution of each different mechanism to the obtained image. More experiments were recently performed using a single-layer thick pancake pickup coil so that the distribution of flaw-induced normal magnetic field component may be measured between the test object and the current sheet, as well as at locations above the current sheet. The test used magnetic current sheet, which has very strong skin depth attenuation. As expected, a distribution of strong magnetic fields exists in between the two conducting sheets; no measurable field strength exists above the magnetic current sheet. Further experiments are being conducted with the new pickup coil to establish a firm theoretical base.
URI: https://yse.yabesh.ir/std/handle/yse/21389
Subject: Research & Development
Collections :
  • NASA - National Aeronautics and Space Administration (NASA)
  • Download PDF : (12.94Kb)
  • Show Full MetaData Hide Full MetaData
  • Statistics

    NASA-LLIS-0526

Show full item record

contributor authorNASA - National Aeronautics and Space Administration (NASA)
date accessioned2017-09-04T15:21:23Z
date available2017-09-04T15:21:23Z
date copyright08/25/1994
date issued1994
identifier otherMZBEQCAAAAAAAAAA.pdf
identifier urihttps://yse.yabesh.ir/std/handle/yse/21389
description abstractDescription of Driving Event:
One of the most important elements for the further improvement of the performance of the magnetooptic imaging instrument is to quantify the contribution of each different mechanism to the obtained image. More experiments were recently performed using a single-layer thick pancake pickup coil so that the distribution of flaw-induced normal magnetic field component may be measured between the test object and the current sheet, as well as at locations above the current sheet. The test used magnetic current sheet, which has very strong skin depth attenuation. As expected, a distribution of strong magnetic fields exists in between the two conducting sheets; no measurable field strength exists above the magnetic current sheet. Further experiments are being conducted with the new pickup coil to establish a firm theoretical base.
languageEnglish
titleNASA-LLIS-0526num
titleLessons Learned – Magnetic Field Distribution in the Magneto-Optic Imaging Instrumenten
typestandard
page2
statusActive
treeNASA - National Aeronautics and Space Administration (NASA):;1994
contenttypefulltext
subject keywordsResearch & Development
subject keywordsTest & Verification
DSpace software copyright © 2017-2020  DuraSpace
نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
yabeshDSpacePersian
 
DSpace software copyright © 2017-2020  DuraSpace
نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
yabeshDSpacePersian