UL 1699 BULLETIN

UL Standard for Safety Arc-Fault Circuit-Interrupters - COMMENTS DUE: October 11, 2010

Organization:
UL - UL
Year: 2010

Abstract: The requirements of this Standard cover arc-fault circuit-interrupters (AFCIs) of the branch/feeder, outlet circuit, portable, and cord type intended for use in dwelling units. These devices are intended to mitigate the effects of arcing faults that may pose a risk of fire ignition under certain conditions if the arcing persists.
AFCIs have a maximum rating of 20 A and are intended for use in 120-V ac, 60-HZ circuits. Cord AFCIs are rated up to 30 A.
These devices are not intended to detect glowing connections.
In these requirements the term device is used generically to apply to all of the devices covered by these requirements and is modified when the requirement does not apply to all types.
An AFCI that is also intended to perform other functions, such as overcurrent protection, ground-fault circuit-interruption, surge suppression, any other similar functions, or any combination thereof, shall comply additionally with the requirements of the applicable Standard or Standards that cover devices that provide those functions.
This standard contains a supplement covering the requirements for Leakage-Current Detector-Interrupters.
URI: https://yse.yabesh.ir/std/handle/yse/215504
Collections :
  • UL - UL
  • Download PDF : (17.97Kb)
  • Show Full MetaData Hide Full MetaData
  • Statistics

    UL 1699 BULLETIN

Show full item record

contributor authorUL - UL
date accessioned2017-09-04T18:33:19Z
date available2017-09-04T18:33:19Z
date copyright09/10/2010
date issued2010
identifier otherJDRMZCAAAAAAAAAA.pdf
identifier urihttps://yse.yabesh.ir/std/handle/yse/215504
description abstractThe requirements of this Standard cover arc-fault circuit-interrupters (AFCIs) of the branch/feeder, outlet circuit, portable, and cord type intended for use in dwelling units. These devices are intended to mitigate the effects of arcing faults that may pose a risk of fire ignition under certain conditions if the arcing persists.
AFCIs have a maximum rating of 20 A and are intended for use in 120-V ac, 60-HZ circuits. Cord AFCIs are rated up to 30 A.
These devices are not intended to detect glowing connections.
In these requirements the term device is used generically to apply to all of the devices covered by these requirements and is modified when the requirement does not apply to all types.
An AFCI that is also intended to perform other functions, such as overcurrent protection, ground-fault circuit-interruption, surge suppression, any other similar functions, or any combination thereof, shall comply additionally with the requirements of the applicable Standard or Standards that cover devices that provide those functions.
This standard contains a supplement covering the requirements for Leakage-Current Detector-Interrupters.
languageEnglish
titleUL 1699 BULLETINnum
titleUL Standard for Safety Arc-Fault Circuit-Interrupters - COMMENTS DUE: October 11, 2010en
typestandard
page2
statusActive
treeUL - UL:;2010
contenttypefulltext
DSpace software copyright © 2017-2020  DuraSpace
نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
yabeshDSpacePersian
 
DSpace software copyright © 2017-2020  DuraSpace
نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
yabeshDSpacePersian