DIN EN 4612-004

English -- Aerospace series - Cables, electrical, for general purpose, single and multicore assembly - XLETFE Family - Jacketed or screened and jacketed - Part 004: Tin plated copper - Operating temperatures, between - 65 °C and 135 °C - Single extruded wall for open applications, with jacket and screen (braid) - UV laser printable - Product standard; German and English version EN 4612-004:2011;
German -- Luft- und Raumfahrt - Ein- und mehradrige elektrische Leitungen zur allgemeinen Verwendung, XLETFE-Familie, ummantelt oder geschirmt und ummantelt - Teil 004: Kupfer verzinnt, Betriebstemperaturen zwischen -65 °C und 135 °C, einfach extrudierte Isolierung fuer offene Anwendungen, ummantelt und geschirmt (Geflecht), UV-Laser bedruckbar - Produktnorm; Deutsche und Englische Fassung EN 4612-004:2011

Organization:
DIN - Deutsches Institut für Normung e. V.
Year: 2012

Abstract: This European Standard specifies the characteristics of UV laser printable jacket, tin plated copper conductor, electrical cables Crosslinked Ethylene Tetra Fluoro Ethylene co-polymer (XLETFE) family for use in the onboard electrical systems of aircraft operating at temperatures between − 65 °C and 135 °C, operating at voltages not exceeding 600 V r.m.s and frequencies not exceeding 2 000 Hz. These cables are suitable for airframe use without additional protection when the jacket is present. When the jacket is stripped back the cores may need additional protection. In case of conflict between this standard and other referenced documents the requirements of this standard shall take precedence.
URI: https://yse.yabesh.ir/std/handle/yse/215911
Subject: Aerospace transport
Collections :
  • DIN - Deutsches Institut für Normung e. V.
  • Download PDF : (447.1Kb)
  • Show Full MetaData Hide Full MetaData
  • Statistics

    DIN EN 4612-004

Show full item record

contributor authorDIN - Deutsches Institut für Normung e. V.
date accessioned2017-09-04T18:33:39Z
date available2017-09-04T18:33:39Z
date copyright2012.02.01
date issued2012
identifier otherJESFUEAAAAAAAAAA.pdf
identifier urihttps://yse.yabesh.ir/std/handle/yse/215911
description abstractThis European Standard specifies the characteristics of UV laser printable jacket, tin plated copper conductor, electrical cables Crosslinked Ethylene Tetra Fluoro Ethylene co-polymer (XLETFE) family for use in the onboard electrical systems of aircraft operating at temperatures between − 65 °C and 135 °C, operating at voltages not exceeding 600 V r.m.s and frequencies not exceeding 2 000 Hz. These cables are suitable for airframe use without additional protection when the jacket is present. When the jacket is stripped back the cores may need additional protection. In case of conflict between this standard and other referenced documents the requirements of this standard shall take precedence.
languageGerman, English
titleDIN EN 4612-004num
titleEnglish -- Aerospace series - Cables, electrical, for general purpose, single and multicore assembly - XLETFE Family - Jacketed or screened and jacketed - Part 004: Tin plated copper - Operating temperatures, between - 65 °C and 135 °C - Single extruded wall for open applications, with jacket and screen (braid) - UV laser printable - Product standard; German and English version EN 4612-004:2011en
titleGerman -- Luft- und Raumfahrt - Ein- und mehradrige elektrische Leitungen zur allgemeinen Verwendung, XLETFE-Familie, ummantelt oder geschirmt und ummantelt - Teil 004: Kupfer verzinnt, Betriebstemperaturen zwischen -65 °C und 135 °C, einfach extrudierte Isolierung fuer offene Anwendungen, ummantelt und geschirmt (Geflecht), UV-Laser bedruckbar - Produktnorm; Deutsche und Englische Fassung EN 4612-004:2011other
typestandard
page26
statusActive
treeDIN - Deutsches Institut für Normung e. V.:;2012
contenttypefulltext
subject keywordsAerospace transport
subject keywordsElectric cables
subject keywordsElectrical engineering
subject keywordselektrisches Kabel
subject keywordsElektrotechnik
subject keywordsLuft- und Raumfahrt
subject keywordsMantelleitung
subject keywordsSheathed cables