UL 1042

UL Standard for Safety Electric Baseboard Heating Equipment - Fifth Edition; Reprint with revisions through and including June 3, 2013

Organization:
UL - UL
Year: 2009

Abstract: These requirements cover portable and fixed electric baseboard heating equipment rated at 600 volts or less, to be employed in ordinary locations in accordance with the National Electrical Code, ANSI/NFPA 70.
Baseboard heating equipment includes baseboard heaters and baseboard heater accessories.
Electric baseboard heating equipment intended for use in a hazardous location is judged on the basis of compliance with the requirements in this standard, together with those recognized requirements applicable to usage in hazardous locations.
Any air heating appliance sold or recommended for use as a baseboard heater, irrespective of its dimensions or other characteristics, is to be identified as a baseboard heater. It will be categorized as a fixed or portable baseboard heater in accordance with the following:
a) Fixed – A heater is identified as a fixed baseboard heater if:
1) The heater is less than 6 in (150 mm) in overall depth, the ratio of the overall length to the overall height is more than two to one, and the heater can be installed completely within a space of 18 in (460 mm) above the floor; or
2) The heater enclosure is intended to be connected to other heater enclosures to form a system.
Exception: A heater intended for ceiling mounting or suspended mounting or marked "Do Not Install Less Than 6 Feet From Floor" is not considered to be a baseboard heater even if it meets the specifications in (1) or (2) above.
b) Portable – A portable heater is identified as a baseboard heater if, excluding projections of guard or feet, it is less than 5 in (130 mm) in depth and if the ratio of its overall length to its height without the handle is as follows:
URI: https://yse.yabesh.ir/std/handle/yse/217049
Collections :
  • UL - UL
  • Download PDF : (1.178Mb)
  • Show Full MetaData Hide Full MetaData
  • Statistics

    UL 1042

Show full item record

contributor authorUL - UL
date accessioned2017-09-04T18:34:52Z
date available2017-09-04T18:34:52Z
date copyright08/31/2009
date issued2009
identifier otherJHRNDFAAAAAAAAAA.pdf
identifier urihttps://yse.yabesh.ir/std/handle/yse/217049
description abstractThese requirements cover portable and fixed electric baseboard heating equipment rated at 600 volts or less, to be employed in ordinary locations in accordance with the National Electrical Code, ANSI/NFPA 70.
Baseboard heating equipment includes baseboard heaters and baseboard heater accessories.
Electric baseboard heating equipment intended for use in a hazardous location is judged on the basis of compliance with the requirements in this standard, together with those recognized requirements applicable to usage in hazardous locations.
Any air heating appliance sold or recommended for use as a baseboard heater, irrespective of its dimensions or other characteristics, is to be identified as a baseboard heater. It will be categorized as a fixed or portable baseboard heater in accordance with the following:
a) Fixed – A heater is identified as a fixed baseboard heater if:
1) The heater is less than 6 in (150 mm) in overall depth, the ratio of the overall length to the overall height is more than two to one, and the heater can be installed completely within a space of 18 in (460 mm) above the floor; or
2) The heater enclosure is intended to be connected to other heater enclosures to form a system.
Exception: A heater intended for ceiling mounting or suspended mounting or marked "Do Not Install Less Than 6 Feet From Floor" is not considered to be a baseboard heater even if it meets the specifications in (1) or (2) above.
b) Portable – A portable heater is identified as a baseboard heater if, excluding projections of guard or feet, it is less than 5 in (130 mm) in depth and if the ratio of its overall length to its height without the handle is as follows:
languageEnglish
titleUL 1042num
titleUL Standard for Safety Electric Baseboard Heating Equipment - Fifth Edition; Reprint with revisions through and including June 3, 2013en
typestandard
page120
statusActive
treeUL - UL:;2009
contenttypefulltext
DSpace software copyright © 2017-2020  DuraSpace
نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
yabeshDSpacePersian
 
DSpace software copyright © 2017-2020  DuraSpace
نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
yabeshDSpacePersian