IEEE C57.12.38

Pad-Mounted-Type, Self-Cooled, Single-Phase Distribution Transformers; High Voltage, 34 500 GrdY/19 920 V and Below, Low Voltage, 240/120 V; 167 kVA and Smalle

Organization:
IEEE - The Institute of Electrical and Electronics Engineers, Inc.
Year: 2009

Abstract: This standard covers certain electrical, dimensional, mechanical characteristics and safety requirements of single-phase, 60 Hz, liquid-filled, self-cooled, pad-mounted, compartmental-type distribution transformers. These transformers are rated 167 kVA and smaller, with the high voltages of 34 500 GrdY/19 920 V and below for operation between one phase and grounded neutral, and low voltage of 240/120 V. These transformers are generally used for step-down purposes from an underground primary cable supply. This standard covers the connector, bushing, and terminal arrangements for radial or loop feed systems. This standard does not cover the electrical and mechanical requirements of any accessory devices that may be supplied with the transformer.
Purpose
This standard is intended to define the electrical, mechanical, dimensional, performance, and interchangeability requirements of the transformers covered under this standard and to assist in the proper selection of such equipment. These requirements will provide a more standard transformer design, which will benefit manufacturers by reducing the number of designs. Users will be provided a document, which can be used to purchase a transformer of standard design, without having to develop any additional standards. This will be helpful to less experienced users. It also will promote standardization of these types of transformers. This standard will replace ANSI C57.12.21-1992 [B1] and ANSI C57.12.25-1990 [B2].1
1 The numbers in brackets correspond to those of the bibliography in Annex A.
URI: https://yse.yabesh.ir/std/handle/yse/218135
Subject: distribution transformers
Collections :
  • IEEE - The Institute of Electrical and Electronics Engineers, Inc.
  • Download PDF : (3.537Mb)
  • Show Full MetaData Hide Full MetaData
  • Statistics

    IEEE C57.12.38

Show full item record

contributor authorIEEE - The Institute of Electrical and Electronics Engineers, Inc.
date accessioned2017-09-04T18:36:09Z
date available2017-09-04T18:36:09Z
date copyright09/11/2009
date issued2009
identifier otherJKMLPCAAAAAAAAAA.pdf
identifier urihttps://yse.yabesh.ir/std/handle/yse/218135
description abstractThis standard covers certain electrical, dimensional, mechanical characteristics and safety requirements of single-phase, 60 Hz, liquid-filled, self-cooled, pad-mounted, compartmental-type distribution transformers. These transformers are rated 167 kVA and smaller, with the high voltages of 34 500 GrdY/19 920 V and below for operation between one phase and grounded neutral, and low voltage of 240/120 V. These transformers are generally used for step-down purposes from an underground primary cable supply. This standard covers the connector, bushing, and terminal arrangements for radial or loop feed systems. This standard does not cover the electrical and mechanical requirements of any accessory devices that may be supplied with the transformer.
Purpose
This standard is intended to define the electrical, mechanical, dimensional, performance, and interchangeability requirements of the transformers covered under this standard and to assist in the proper selection of such equipment. These requirements will provide a more standard transformer design, which will benefit manufacturers by reducing the number of designs. Users will be provided a document, which can be used to purchase a transformer of standard design, without having to develop any additional standards. This will be helpful to less experienced users. It also will promote standardization of these types of transformers. This standard will replace ANSI C57.12.21-1992 [B1] and ANSI C57.12.25-1990 [B2].1
1 The numbers in brackets correspond to those of the bibliography in Annex A.
languageEnglish
titleIEEE C57.12.38num
titlePad-Mounted-Type, Self-Cooled, Single-Phase Distribution Transformers; High Voltage, 34 500 GrdY/19 920 V and Below, Low Voltage, 240/120 V; 167 kVA and Smalleen
typestandard
page30
statusActive
treeIEEE - The Institute of Electrical and Electronics Engineers, Inc.:;2009
contenttypefulltext
subject keywordsdistribution transformers
subject keywordspadmounted
subject keywordspad-mounted
subject keywordssingle phase
subject keywordssingle-phase
subject keywordstransformer