• 0
    • ارسال درخواست
    • حذف همه
    • Industrial Standards
    • Defence Standards
  • درباره ما
  • درخواست موردی
  • فهرست استانداردها
    • Industrial Standards
    • Defence Standards
  • راهنما
  • Login
  • لیست خرید شما 0
    • ارسال درخواست
    • حذف همه
View Item 
  •   YSE
  • Industrial Standards
  • DIN - Deutsches Institut für Normung e. V.
  • View Item
  •   YSE
  • Industrial Standards
  • DIN - Deutsches Institut für Normung e. V.
  • View Item
  • All Fields
  • Title(or Doc Num)
  • Organization
  • Year
  • Subject
Advanced Search
JavaScript is disabled for your browser. Some features of this site may not work without it.

Archive

DIN EN ISO 3741

English -- Acoustics - Determination of sound power levels and sound energy levels of noise sources using sound pressure - Precision methods for reverberation test rooms (ISO 3741:2010);
German -- Akustik - Bestimmung der Schallleistungs- und Schallenergiepegel von Geraeuschquellen aus Schalldruckmessungen - Hallraumverfahren der Genauigkeitsklasse 1 (ISO 3741:2010)

Organization:
DIN - Deutsches Institut für Normung e. V.
Year: 2011

Abstract: General
This International Standard specifies methods for determining the sound power level or sound energy level of a noise source from sound pressure levels measured in a reverberation test room. The sound power level (or, in the case of noise bursts or transient noise emission, the sound energy level) produced by the noise source, in frequency bands of width one-third-octave, is calculated using those measurements, including corrections to allow for any differences between the meteorological conditions at the time and place of the test and those corresponding to a reference characteristic impedance. Measurement and calculation procedures are given for both a direct method and a comparison method of determining the sound power level and the sound energy level.
In general, the frequency range of interest includes the one-third-octave bands with mid-band frequencies from 100 Hz to 10 000 Hz. Guidelines for the application of the specified methods over an extended frequency range in respect to lower frequencies are given in Annex E. This International Standard is not applicable to frequency ranges above the 10 000 Hz one-third-octave band.
NOTE For higher frequencies, the methods specified in ISO 9295 can be used.
Types of noise and noise sources
The methods specified in this International Standard are suitable for all types of noise (steady, non-steady, fluctuating, isolated bursts of sound energy, etc.) defined in ISO 12001.
The noise source under test can be a device, machine, component or sub-assembly. This International Standard is applicable to noise sources with a volume not greater than 2 % of the volume of the reverberation test room. For a source with a volume greater than 2 % of the volume of the test room, it is possible that the achievement of results as defined in ISO 12001:1996, accuracy grade 1 (precision grade) is not feasible.
NOTE In specific cases, the source volume can be increased to a maximum of 5 % of the room volume. In such cases, the relevant noise test code indicates the possible consequences on the measurement uncertainty.
Reverberation test room
The test rooms that are applicable for measurements made in accordance with this International Standard are reverberation test rooms meeting specified requirements (see Clause 5).
Measurement uncertainty
Information is given on the uncertainty of the sound power levels and sound energy levels determined in accordance with this International Standard, for measurements made in specific frequency bands and for the A-weighted sum of all frequency bands. The uncertainty conforms to ISO 12001:1996, accuracy grade 1 (precision grade).
URI: https://yse.yabesh.ir/std/handle/yse/222490
Subject: Acoustics
Collections :
  • DIN - Deutsches Institut für Normung e. V.
  • Download PDF : (940.9Kb)
  • Show Full MetaData Hide Full MetaData
  • Statistics

    DIN EN ISO 3741

Show full item record

contributor authorDIN - Deutsches Institut für Normung e. V.
date accessioned2017-09-04T18:40:50Z
date available2017-09-04T18:40:50Z
date copyright2011.01.01
date issued2011
identifier otherJVWABEAAAAAAAAAA.pdf
identifier urihttps://yse.yabesh.ir/std/handle/yse/222490
description abstractGeneral
This International Standard specifies methods for determining the sound power level or sound energy level of a noise source from sound pressure levels measured in a reverberation test room. The sound power level (or, in the case of noise bursts or transient noise emission, the sound energy level) produced by the noise source, in frequency bands of width one-third-octave, is calculated using those measurements, including corrections to allow for any differences between the meteorological conditions at the time and place of the test and those corresponding to a reference characteristic impedance. Measurement and calculation procedures are given for both a direct method and a comparison method of determining the sound power level and the sound energy level.
In general, the frequency range of interest includes the one-third-octave bands with mid-band frequencies from 100 Hz to 10 000 Hz. Guidelines for the application of the specified methods over an extended frequency range in respect to lower frequencies are given in Annex E. This International Standard is not applicable to frequency ranges above the 10 000 Hz one-third-octave band.
NOTE For higher frequencies, the methods specified in ISO 9295 can be used.
Types of noise and noise sources
The methods specified in this International Standard are suitable for all types of noise (steady, non-steady, fluctuating, isolated bursts of sound energy, etc.) defined in ISO 12001.
The noise source under test can be a device, machine, component or sub-assembly. This International Standard is applicable to noise sources with a volume not greater than 2 % of the volume of the reverberation test room. For a source with a volume greater than 2 % of the volume of the test room, it is possible that the achievement of results as defined in ISO 12001:1996, accuracy grade 1 (precision grade) is not feasible.
NOTE In specific cases, the source volume can be increased to a maximum of 5 % of the room volume. In such cases, the relevant noise test code indicates the possible consequences on the measurement uncertainty.
Reverberation test room
The test rooms that are applicable for measurements made in accordance with this International Standard are reverberation test rooms meeting specified requirements (see Clause 5).
Measurement uncertainty
Information is given on the uncertainty of the sound power levels and sound energy levels determined in accordance with this International Standard, for measurements made in specific frequency bands and for the A-weighted sum of all frequency bands. The uncertainty conforms to ISO 12001:1996, accuracy grade 1 (precision grade).
languageEnglish
titleDIN EN ISO 3741num
titleEnglish -- Acoustics - Determination of sound power levels and sound energy levels of noise sources using sound pressure - Precision methods for reverberation test rooms (ISO 3741:2010)en
titleGerman -- Akustik - Bestimmung der Schallleistungs- und Schallenergiepegel von Geraeuschquellen aus Schalldruckmessungen - Hallraumverfahren der Genauigkeitsklasse 1 (ISO 3741:2010)other
typestandard
page70
statusActive
treeDIN - Deutsches Institut für Normung e. V.:;2011
contenttypefulltext
subject keywordsAcoustics
subject keywordsAkustik
subject keywordsLaerm
subject keywordsNoise (environmental)
subject keywordsPruefverfahren
subject keywordsSchallpegel
subject keywordsSound levels
subject keywordsTesting