Show simple item record

English -- Safety devices for protection against excessive pressure - Part 7: Common data (ISO 4126-7:2013 + Amd 1:2016) (includes Amendment A1:2016);
German -- Sicherheitseinrichtungen gegen unzulaessigen Ueberdruck - Teil 7: Allgemeine Daten (ISO 4126-7:2013 + Amd 1:2016) (enthaelt Aenderung A1:2016)

contributor authorDIN - Deutsches Institut fš?r Normung e. V.
date accessioned2017-10-18T11:00:55Z
date available2017-10-18T11:00:55Z
date copyright2016.12.01
date issued2016
identifier otherMOOKTFAAAAAAAAAA.pdf
identifier urihttps://yse.yabesh.ir/std/handle/yse/233713
description abstractScope: This part of ISO 4126 specifies requirements for safety valves. It contains information which is common to ISO 4126-1 to ISO 4126-6 to avoid unnecessary repetition. For flashing liquids or two-phase mixtures, see ISO 4126-10. The user is cautioned that it is not recommended to use the ideal gas formula presented in 6.3 when the relieving temperature is greater than 90 % of the thermodynamic critical temperature and the relieving pressure is greater than 50 % of the thermodynamic critical pressure. Additionally, condensation is not considered. If condensation occurs, the method presented in 6.3 should not be used.
languageEnglish
titleDIN EN ISO 4126-7num
titleEnglish -- Safety devices for protection against excessive pressure - Part 7: Common data (ISO 4126-7:2013 + Amd 1:2016) (includes Amendment A1:2016)en
titleGerman -- Sicherheitseinrichtungen gegen unzulaessigen Ueberdruck - Teil 7: Allgemeine Daten (ISO 4126-7:2013 + Amd 1:2016) (enthaelt Aenderung A1:2016)other
typestandard
page42
statusActive
treeDIN - Deutsches Institut fš?r Normung e. V.:;2016
contenttypefulltext


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record