DIN EN ISO 4126-7
English -- Safety devices for protection against excessive pressure - Part 7: Common data (ISO 4126-7:2013 + Amd 1:2016) (includes Amendment A1:2016);
German -- Sicherheitseinrichtungen gegen unzulaessigen Ueberdruck - Teil 7: Allgemeine Daten (ISO 4126-7:2013 + Amd 1:2016) (enthaelt Aenderung A1:2016)
Organization:
DIN - Deutsches Institut fš?r Normung e. V.
Year: 2016
Abstract: Scope: This part of ISO 4126 specifies requirements for safety valves. It contains information which is common to ISO 4126-1 to ISO 4126-6 to avoid unnecessary repetition. For flashing liquids or two-phase mixtures, see ISO 4126-10. The user is cautioned that it is not recommended to use the ideal gas formula presented in 6.3 when the relieving temperature is greater than 90 % of the thermodynamic critical temperature and the relieving pressure is greater than 50 % of the thermodynamic critical pressure. Additionally, condensation is not considered. If condensation occurs, the method presented in 6.3 should not be used.
Collections
:
-
Statistics
DIN EN ISO 4126-7
Show full item record
| contributor author | DIN - Deutsches Institut fš?r Normung e. V. | |
| date accessioned | 2017-10-18T11:00:55Z | |
| date available | 2017-10-18T11:00:55Z | |
| date copyright | 2016.12.01 | |
| date issued | 2016 | |
| identifier other | MOOKTFAAAAAAAAAA.pdf | |
| identifier uri | https://yse.yabesh.ir/std/handle/yse/233713 | |
| description abstract | Scope: This part of ISO 4126 specifies requirements for safety valves. It contains information which is common to ISO 4126-1 to ISO 4126-6 to avoid unnecessary repetition. For flashing liquids or two-phase mixtures, see ISO 4126-10. The user is cautioned that it is not recommended to use the ideal gas formula presented in 6.3 when the relieving temperature is greater than 90 % of the thermodynamic critical temperature and the relieving pressure is greater than 50 % of the thermodynamic critical pressure. Additionally, condensation is not considered. If condensation occurs, the method presented in 6.3 should not be used. | |
| language | English | |
| title | DIN EN ISO 4126-7 | num |
| title | English -- Safety devices for protection against excessive pressure - Part 7: Common data (ISO 4126-7:2013 + Amd 1:2016) (includes Amendment A1:2016) | en |
| title | German -- Sicherheitseinrichtungen gegen unzulaessigen Ueberdruck - Teil 7: Allgemeine Daten (ISO 4126-7:2013 + Amd 1:2016) (enthaelt Aenderung A1:2016) | other |
| type | standard | |
| page | 42 | |
| status | Active | |
| tree | DIN - Deutsches Institut fš?r Normung e. V.:;2016 | |
| contenttype | fulltext |