IEEE Guide for Tank Rupture Mitigation of Liquid-Immersed Power Transformers and Reactors

IEEE Std C57.156-2016

Organization:
IEEE - The Institute of Electrical and Electronics Engineers, Inc.
Year: 2016

Abstract: Measures that may be taken to help mitigate tank rupture of energized liquid-immersed power transformers and reactors due to internal electrical faults are described in this guide. The release of insulating fluid or insulating fluid mist due to failure of the following components are not covered in this guide: load tap changer compartments, bushings and their turrets, conservator tank, piping, valves, pumps, and radiators.
URI: https://yse.yabesh.ir/std/handle/yse/240436
Subject: IEEE C57.156(TM)
Collections :
  • IEEE - The Institute of Electrical and Electronics Engineers, Inc.
  • Download PDF : (2.019Mb)
  • Show Full MetaData Hide Full MetaData
  • Statistics

    IEEE Guide for Tank Rupture Mitigation of Liquid-Immersed Power Transformers and Reactors

Show full item record

contributor authorIEEE - The Institute of Electrical and Electronics Engineers, Inc.
date accessioned2017-10-28T13:02:00Z
date available2017-10-28T13:02:00Z
date copyright21 Dec. 2016
date issued2016
identifier other7792305.pdf
identifier urihttps://yse.yabesh.ir/std/handle/yse/240436
description abstractMeasures that may be taken to help mitigate tank rupture of energized liquid-immersed power transformers and reactors due to internal electrical faults are described in this guide. The release of insulating fluid or insulating fluid mist due to failure of the following components are not covered in this guide: load tap changer compartments, bushings and their turrets, conservator tank, piping, valves, pumps, and radiators.
languageEnglish
titleIEEE Guide for Tank Rupture Mitigation of Liquid-Immersed Power Transformers and Reactorsen
titleIEEE Std C57.156-2016num
typestandard
page26
treeIEEE - The Institute of Electrical and Electronics Engineers, Inc.:;2016
contenttypefulltext
subject keywordsIEEE C57.156(TM)
subject keywordsmitigation
subject keywordstank
identifier DOI10.1109/IEEESTD.2016.7792305