IEEE Standard for Test Methods and Performance of Low-Voltage (1000 V rms or Less) Surge Protective Devices Used on Secondary Distribution Systems (Between the Transformer Low-Voltage Terminals and the Line Side of the Service Equipment)
IEEE Std C62.34-2017 (Revision of IEEE Std C62.34-1996)
Year: 2017
Abstract: This standard applies to surge protective devices designed for application on the low-voltage supply mains (1000 V rms and less, frequency between 48 Hz and 62 Hz) and intended to be connected at locations between, and including, the secondary terminals of the distribution transformer and the line side of the service equipment. Such surge protective devices are also known as secondary arresters. This is coordinated with IEEE Std C62.44 (the application guide),NEC Article 285, and ANSI/UL 1449.
Subject: IEEE C62.34(TM)
-
Statistics
IEEE Standard for Test Methods and Performance of Low-Voltage (1000 V rms or Less) Surge Protective Devices Used on Secondary Distribution Systems (Between the Transformer Low-Voltage Terminals and the Line Side of the Service Equipment)
Show full item record
| contributor author | IEEE - The Institute of Electrical and Electronics Engineers, Inc. | |
| date accessioned | 2018-07-30T06:05:20Z | |
| date available | 2018-07-30T06:05:20Z | |
| date copyright | Oct. 27 2017 | |
| date issued | 2017 | |
| identifier isbn | Electronic:978-1-5044-4325-8 | |
| identifier other | 8082844.pdf | |
| identifier uri | https://yse.yabesh.ir/std/handle/yse/258346 | |
| description abstract | This standard applies to surge protective devices designed for application on the low-voltage supply mains (1000 V rms and less, frequency between 48 Hz and 62 Hz) and intended to be connected at locations between, and including, the secondary terminals of the distribution transformer and the line side of the service equipment. Such surge protective devices are also known as secondary arresters. This is coordinated with IEEE Std C62.44 (the application guide),NEC Article 285, and ANSI/UL 1449. | |
| language | English | |
| title | IEEE Standard for Test Methods and Performance of Low-Voltage (1000 V rms or Less) Surge Protective Devices Used on Secondary Distribution Systems (Between the Transformer Low-Voltage Terminals and the Line Side of the Service Equipment) | en |
| title | IEEE Std C62.34-2017 (Revision of IEEE Std C62.34-1996) | num |
| type | standard | |
| page | 40 | |
| tree | IEEE - The Institute of Electrical and Electronics Engineers, Inc.:;2017 | |
| contenttype | fulltext | |
| subject keywords | IEEE C62.34(TM) | |
| subject keywords | SPDs | |
| subject keywords | Type 1 SPDs | |
| subject keywords | low voltage | |
| subject keywords | secondary arresters | |
| subject keywords | surge protective devices | |
| subject keywords | Arresters | |
| subject keywords | IEEE Standards | |
| subject keywords | Low power electronics | |
| subject keywords | Low voltage | |
| subject keywords | Performance evaluation | |
| subject keywords | Surge protection | |
| subject keywords | Voltage control | |
| identifier DOI | 10.1109/IEEESTD.2017.8082844 |

درباره ما