• 0
    • ارسال درخواست
    • حذف همه
    • Industrial Standards
    • Defence Standards
  • درباره ما
  • درخواست موردی
  • فهرست استانداردها
    • Industrial Standards
    • Defence Standards
  • راهنما
  • Login
  • لیست خرید شما 0
    • ارسال درخواست
    • حذف همه
View Item 
  •   YSE
  • Industrial Standards
  • IEEE - The Institute of Electrical and Electronics Engineers, Inc.
  • View Item
  •   YSE
  • Industrial Standards
  • IEEE - The Institute of Electrical and Electronics Engineers, Inc.
  • View Item
  • All Fields
  • Title(or Doc Num)
  • Organization
  • Year
  • Subject
Advanced Search
JavaScript is disabled for your browser. Some features of this site may not work without it.

Archive

Determining the peak spatial-average specific absorption rate (SAR) in the human body from wireless communications devices, 30 MHz to 6 GHz - Part 3: Specific requirements for using the finite difference time domain (FDTD) method for SAR calculations of m

IEC/IEEE 62704-3:2017

Organization:
IEEE - The Institute of Electrical and Electronics Engineers, Inc.
Year: 2017

Abstract: This part of IEC/IEEE 62704 defines the concepts, techniques, benchmark phone models, validation procedures, uncertainties and limitations of the finite difference time domain (FDTD) technique when used for determining the peak spatial-average specific absorption rate (SAR) in standardized head and body phantoms exposed to the electromagnetic fields generated by wireless communication devices, in particular pre-compliance assessment of mobile phones, in the frequency range from 30 MHz to 6 GHz. It recommends and provides guidance on the numerical modelling of mobile phones and benchmark results to verify the general approach for the numerical simulations of such devices. It defines acceptable modelling requirements, guidance on meshing and test positions of the mobile phone and the phantom models. This document does not recommend specific SAR limits since these are found in other documents, e.g. IEEE C95.1-2005[1]2 and ICNIRP[2].
URI: https://yse.yabesh.ir/std/handle/yse/258361
Subject: Biomedical measurements
Collections :
  • IEEE - The Institute of Electrical and Electronics Engineers, Inc.
  • Download PDF : (2.373Mb)
  • Show Full MetaData Hide Full MetaData
  • Statistics

    Determining the peak spatial-average specific absorption rate (SAR) in the human body from wireless communications devices, 30 MHz to 6 GHz - Part 3: Specific requirements for using the finite difference time domain (FDTD) method for SAR calculations of m

Show full item record

contributor authorIEEE - The Institute of Electrical and Electronics Engineers, Inc.
date accessioned2018-07-30T06:05:24Z
date available2018-07-30T06:05:24Z
date copyrightOct. 27 2017
date issued2017
identifier isbnElectronic:978-1-5044-4261-9
identifier other8089724.pdf
identifier urihttps://yse.yabesh.ir/std/handle/yse/258361
description abstractThis part of IEC/IEEE 62704 defines the concepts, techniques, benchmark phone models, validation procedures, uncertainties and limitations of the finite difference time domain (FDTD) technique when used for determining the peak spatial-average specific absorption rate (SAR) in standardized head and body phantoms exposed to the electromagnetic fields generated by wireless communication devices, in particular pre-compliance assessment of mobile phones, in the frequency range from 30 MHz to 6 GHz. It recommends and provides guidance on the numerical modelling of mobile phones and benchmark results to verify the general approach for the numerical simulations of such devices. It defines acceptable modelling requirements, guidance on meshing and test positions of the mobile phone and the phantom models. This document does not recommend specific SAR limits since these are found in other documents, e.g. IEEE C95.1-2005[1]2 and ICNIRP[2].
languageEnglish
titleDetermining the peak spatial-average specific absorption rate (SAR) in the human body from wireless communications devices, 30 MHz to 6 GHz - Part 3: Specific requirements for using the finite difference time domain (FDTD) method for SAR calculations of men
titleIEC/IEEE 62704-3:2017num
typestandard
page76
treeIEEE - The Institute of Electrical and Electronics Engineers, Inc.:;2017
contenttypefulltext
subject keywordsBiomedical measurements
subject keywordsBiomedical monitoring
subject keywordsFinite difference methods
subject keywordsIEC Standards
subject keywordsIEEE Standards
subject keywordsSolid modeling
subject keywordsSpecific absorption rate
subject keywordsTime-domain analysis
subject keywordsbiological effects of fields
subject keywordsbiological effects of microwaves
subject keywordselectromagnetic wave absorption
subject keywordsfinite difference time-domain analysis
subject keywordsmobile handsets
subject keywordsradiocommunication
subject keywordsFDTD method
subject keywordsICNIRP
subject keywordsIEC/IEEE 62704
subject keywordsIEEE C95.1-2005[1]2
subject keywordsSAR calculations
subject keywordsbody phantoms
subject keywordselectromagnetic field exposure
subject keywordsfinite difference time domain method
subject keywordsfrequency 30 MHz to 6 GHz
subject keywordshead phantoms
subject keywordshuman body
subject keywordsmobile phones
subject keywordspeak spatial-average specific absorption rate
subject keywordswireless communications devices
identifier DOI10.1109/IEEESTD.2017.8089724
DSpace software copyright © 2017-2020  DuraSpace
نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
yabeshDSpacePersian
 
DSpace software copyright © 2017-2020  DuraSpace
نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
yabeshDSpacePersian