Archive

IEEE Recommended Practice for Preferred Ratings for High-Voltage(>1000 volts) AC Circuit Breakers Designated Definite Purpose for Fast Transient Recovery Voltage Rise Times

IEEE Std C37.06.1-2017

Organization:
IEEE - The Institute of Electrical and Electronics Engineers, Inc.
Year: 2018

Abstract: The preferred ratings of transformer-limited fault duty (fast transient recovery voltage rise times) of indoor and outdoor high-voltage circuit breakers rated above 1000 V for use in commercial, industrial, and utility installations are described.
URI: https://yse.yabesh.ir/std/handle/yse/258412
Subject: IEEE C37.06.1(TM)
Collections :
  • IEEE - The Institute of Electrical and Electronics Engineers, Inc.
  • Download PDF : (2.849Mb)
  • Show Full MetaData Hide Full MetaData
  • Statistics

    IEEE Recommended Practice for Preferred Ratings for High-Voltage(>1000 volts) AC Circuit Breakers Designated Definite Purpose for Fast Transient Recovery Voltage Rise Times

Show full item record

contributor authorIEEE - The Institute of Electrical and Electronics Engineers, Inc.
date accessioned2018-07-30T06:09:54Z
date available2018-07-30T06:09:54Z
date copyrightFeb. 6 2018
date issued2018
identifier isbn9781504445818
identifier other08283963.pdf
identifier urihttps://yse.yabesh.ir/std/handle/yse/258412
description abstractThe preferred ratings of transformer-limited fault duty (fast transient recovery voltage rise times) of indoor and outdoor high-voltage circuit breakers rated above 1000 V for use in commercial, industrial, and utility installations are described.
languageEnglish
titleIEEE Recommended Practice for Preferred Ratings for High-Voltage(>1000 volts) AC Circuit Breakers Designated Definite Purpose for Fast Transient Recovery Voltage Rise Timesen
titleIEEE Std C37.06.1-2017num
typestandard
page26
treeIEEE - The Institute of Electrical and Electronics Engineers, Inc.:;2018
contenttypefulltext
subject keywordsIEEE C37.06.1(TM)
subject keywordsTRV
subject keywordsfast transient recovery voltage rise times
subject keywordshigh-voltage circuit breakers
subject keywordstransformer-limited fault
subject keywordstransient recovery voltage
subject keywordsCircuit breakers
subject keywordsHigh-voltage techniques
subject keywordsIEEE Standards
subject keywordsPower transformers
subject keywordsSystem recovery
subject keywordsTransient analysis
subject keywordsVoltage control
subject keywordsIEEE standards
subject keywordscircuit breakers
subject keywordstransients
subject keywordsIEEE Std C37.06.1-2017
subject keywordsfast transient recovery voltage rise times
subject keywordshigh-voltage AC circuit breakers
subject keywordstransformer-limited fault duty
identifier DOI10.1109/IEEESTD.2018.8283963
DSpace software copyright © 2017-2020  DuraSpace
نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
yabeshDSpacePersian
 
DSpace software copyright © 2017-2020  DuraSpace
نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
yabeshDSpacePersian