NASA-LLIS-0612
Lessons Learned – Fault Protection of Wax Thermal Actuator Applications (1998)
Year: 1999
Abstract: Abstract:
ghteen days after launch of Deep Space 1, a spurious signal issued by the power distribution logic re-powered the primary heaters on the wax thermal actuators that had been used to release the DS1 solar arrays. The resulting short-circuit current could easily have damaged the power subsystem and jeopardized the mission. Power distribution circuitry should be designed to preclude inadvertent powering of wax thermal actuator heaters. Wax actuator circuitry should be designed to prevent a failure that leaves actuator heaters powered for an excessive period of time.
ghteen days after launch of Deep Space 1, a spurious signal issued by the power distribution logic re-powered the primary heaters on the wax thermal actuators that had been used to release the DS1 solar arrays. The resulting short-circuit current could easily have damaged the power subsystem and jeopardized the mission. Power distribution circuitry should be designed to preclude inadvertent powering of wax thermal actuator heaters. Wax actuator circuitry should be designed to prevent a failure that leaves actuator heaters powered for an excessive period of time.
Subject: Electrical Short
Show full item record
| contributor author | NASA - National Aeronautics and Space Administration (NASA) | |
| date accessioned | 2017-09-04T15:25:43Z | |
| date available | 2017-09-04T15:25:43Z | |
| date copyright | 03/04/1999 | |
| date issued | 1999 | |
| identifier other | NMCEQCAAAAAAAAAA.pdf | |
| identifier uri | https://yse.yabesh.ir/std/handle/yse/26344 | |
| description abstract | Abstract: ghteen days after launch of Deep Space 1, a spurious signal issued by the power distribution logic re-powered the primary heaters on the wax thermal actuators that had been used to release the DS1 solar arrays. The resulting short-circuit current could easily have damaged the power subsystem and jeopardized the mission. Power distribution circuitry should be designed to preclude inadvertent powering of wax thermal actuator heaters. Wax actuator circuitry should be designed to prevent a failure that leaves actuator heaters powered for an excessive period of time. | |
| language | English | |
| title | NASA-LLIS-0612 | num |
| title | Lessons Learned – Fault Protection of Wax Thermal Actuator Applications (1998) | en |
| type | standard | |
| page | 3 | |
| status | Active | |
| tree | NASA - National Aeronautics and Space Administration (NASA):;1999 | |
| contenttype | fulltext | |
| subject keywords | Electrical Short | |
| subject keywords | HOP Actuator | |
| subject keywords | Parts Materials & Processes | |
| subject keywords | Pyro | |
| subject keywords | Wax Actuator |