IEEE Standard Requirements for High-Voltage Interrupter Switches, Interrupters, or Interrupting Aids Used on or Attached to Switches Rated for Alternating Currents Above 1000 V
IEEE Std C37.30.3-2018
Year: 2018
Abstract: Requirements for interrupter switches, interrupters or interrupting aids used on or attached to switches rated for high-voltage ac above 1000 V and used indoors, outdoors, or in enclosures for non-fault current interrupting for which an interrupting duty is assigned are covered in this standard. It includes preferred ratings, construction, application, loading, installation, and operation and maintenance guidelines. This standard does not apply to load-break separable insulated connectors, circuit breakers, circuit switchers, metal enclosed switchgear, pad-mounted switchgear, reclosers, sectionalizers or other switching devices that are covered by other IEEE standards.
Subject: high-voltage switches
-
Statistics
IEEE Standard Requirements for High-Voltage Interrupter Switches, Interrupters, or Interrupting Aids Used on or Attached to Switches Rated for Alternating Currents Above 1000 V
Show full item record
| contributor author | IEEE - The Institute of Electrical and Electronics Engineers, Inc. | |
| date accessioned | 2019-07-24T09:05:37Z | |
| date available | 2019-07-24T09:05:37Z | |
| date issued | 2018 | |
| identifier isbn | 978-1-5044-5013 | |
| identifier other | 08481665.pdf | |
| identifier uri | https://yse.yabesh.ir/std/handle/yse/273548 | |
| description abstract | Requirements for interrupter switches, interrupters or interrupting aids used on or attached to switches rated for high-voltage ac above 1000 V and used indoors, outdoors, or in enclosures for non-fault current interrupting for which an interrupting duty is assigned are covered in this standard. It includes preferred ratings, construction, application, loading, installation, and operation and maintenance guidelines. This standard does not apply to load-break separable insulated connectors, circuit breakers, circuit switchers, metal enclosed switchgear, pad-mounted switchgear, reclosers, sectionalizers or other switching devices that are covered by other IEEE standards. | |
| language | English | |
| title | IEEE Standard Requirements for High-Voltage Interrupter Switches, Interrupters, or Interrupting Aids Used on or Attached to Switches Rated for Alternating Currents Above 1000 V | en |
| title | IEEE Std C37.30.3-2018 | num |
| type | Standard | |
| page | 30 | |
| tree | IEEE - The Institute of Electrical and Electronics Engineers, Inc.:;2018 | |
| contenttype | Fulltext | |
| subject keywords | high-voltage switches | |
| subject keywords | IEEE C37.30.3â„¢ | |
| subject keywords | indoor switches | |
| subject keywords | interrupter switches | |
| subject keywords | outdoor switches | |
| subject keywords | IEEE Standards | |
| subject keywords | High-voltage techniques | |
| subject keywords | Switchgear | |
| subject keywords | Interrupters | |
| subject keywords | Voltage control | |
| identifier DOI | 10.1109/IEEESTD.2018.8481665 |