• 0
    • ارسال درخواست
    • حذف همه
    • Industrial Standards
    • Defence Standards
  • درباره ما
  • درخواست موردی
  • فهرست استانداردها
    • Industrial Standards
    • Defence Standards
  • راهنما
  • Login
  • لیست خرید شما 0
    • ارسال درخواست
    • حذف همه
View Item 
  •   YSE
  • Industrial Standards
  • IEEE - The Institute of Electrical and Electronics Engineers, Inc.
  • View Item
  •   YSE
  • Industrial Standards
  • IEEE - The Institute of Electrical and Electronics Engineers, Inc.
  • View Item
  • All Fields
  • Title(or Doc Num)
  • Organization
  • Year
  • Subject
Advanced Search
JavaScript is disabled for your browser. Some features of this site may not work without it.

Archive

IEEE Recommended Practice for Performing Temperature Rise Tests on Liquid-Immersed Power Transformers at Loads Beyond Nameplate Ratings

IEEE Std C57.119-2018 (Revision of IEEE Std C57.119-2001)

Organization:
IEEE - The Institute of Electrical and Electronics Engineers, Inc.
Year: 2018

Abstract: Recommendations are made, where possible, regarding the performance and evaluation of temperature rise tests on liquid-immersed power transformers beyond nameplate ratings in this recommended practice. The intent is to assist power transformer manufacturers, and the ultimate users, in evaluating thermal performance of the transformers under varying loads.
URI: https://yse.yabesh.ir/std/handle/yse/273554
Subject: bottom oil temperature
Collections :
  • IEEE - The Institute of Electrical and Electronics Engineers, Inc.
  • Download PDF : (2.108Mb)
  • Show Full MetaData Hide Full MetaData
  • Statistics

    IEEE Recommended Practice for Performing Temperature Rise Tests on Liquid-Immersed Power Transformers at Loads Beyond Nameplate Ratings

Show full item record

contributor authorIEEE - The Institute of Electrical and Electronics Engineers, Inc.
date accessioned2019-07-24T09:05:38Z
date available2019-07-24T09:05:38Z
date issued2018
identifier isbn978-1-5044-4982
identifier other08495141.pdf
identifier urihttps://yse.yabesh.ir/std/handle/yse/273554
description abstractRecommendations are made, where possible, regarding the performance and evaluation of temperature rise tests on liquid-immersed power transformers beyond nameplate ratings in this recommended practice. The intent is to assist power transformer manufacturers, and the ultimate users, in evaluating thermal performance of the transformers under varying loads.
languageEnglish
titleIEEE Recommended Practice for Performing Temperature Rise Tests on Liquid-Immersed Power Transformers at Loads Beyond Nameplate Ratingsen
titleIEEE Std C57.119-2018 (Revision of IEEE Std C57.119-2001)num
typeStandard
page49
treeIEEE - The Institute of Electrical and Electronics Engineers, Inc.:;2018
contenttypeFulltext
subject keywordsbottom oil temperature
subject keywordsconditioning loads
subject keywordshottest spot factor
subject keywordsIEEE C57.119â„¢
subject keywordsliquidimmersed
subject keywordsloading
subject keywordsload tap changer
subject keywordspower transformers
subject keywordsrated load
subject keywordsthermal capacity
subject keywordstop oil temperature
subject keywordsIEEE Standards
subject keywordsImmersion cooling
subject keywordsLiquid cooling
subject keywordsTemperature measurement
subject keywordsPower transformers
subject keywordsLoad management
identifier DOI10.1109/IEEESTD.2018.8495141
DSpace software copyright © 2017-2020  DuraSpace
نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
yabeshDSpacePersian
 
DSpace software copyright © 2017-2020  DuraSpace
نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
yabeshDSpacePersian