Wiring Distribution Systems for Off-Road, Self-Propelled Work Machines
J1614_201811
Organization:
SAE - SAE International
Year: 2018
Abstract: This SAE Standard specifies requirements and design guidelines for electrical wiring systems of less than 50 V and cable diameters from 0.35 to 19 mm2 used on off-road, self-propelled earthmoving machines as defined in SAE J1116 and agricultural tractors as defined in ASAE S390.
Collections
:
-
Statistics
Wiring Distribution Systems for Off-Road, Self-Propelled Work Machines
Show full item record
| contributor author | SAE - SAE International | |
| date accessioned | 2019-07-30T11:22:44Z | |
| date available | 2019-07-30T11:22:44Z | |
| date copyright | 11/21/2018 12:00:00 AM | |
| date issued | 2018 | |
| identifier other | J1614_201811.pdf | |
| identifier uri | https://yse.yabesh.ir/std/handle/yse/273763 | |
| description abstract | This SAE Standard specifies requirements and design guidelines for electrical wiring systems of less than 50 V and cable diameters from 0.35 to 19 mm2 used on off-road, self-propelled earthmoving machines as defined in SAE J1116 and agricultural tractors as defined in ASAE S390. | |
| language | English | |
| title | Wiring Distribution Systems for Off-Road, Self-Propelled Work Machines | en |
| title | J1614_201811 | num |
| type | Standard | |
| tree | SAE - SAE International:;2018 | |
| contenttype | Fulltext | |
| identifier DOI | 10.4271/J1614_201811 |