IEEE Standard Performance Requirements and Test Methods for Tap-Changers

IEEE Std C57.131-2024 (Revision of IEEE Std C57.131-2012)

Organization:
IEEE - The Institute of Electrical and Electronics Engineers, Inc.
Year: 2024

IEEE - The Institute of Electrical and Electronics Engineers, Inc.

Abstract: Electrical and mechanical performance and test requirements for on-load tap-changers of both resistor and reactor types, de-energized tap-changers, and their motor-drive mechanisms installed in power and distribution transformers, reactors, and voltage regulators are covered.
URI: https://yse.yabesh.ir/std/handle/yse/336490
Subject: equalizer winding
Collections :
  • IEEE - The Institute of Electrical and Electronics Engineers, Inc.
  • Download PDF : (1.943Mb)
  • Show Full MetaData Hide Full MetaData
  • Statistics

    IEEE Standard Performance Requirements and Test Methods for Tap-Changers

Show full item record

contributor authorIEEE - The Institute of Electrical and Electronics Engineers, Inc.
date accessioned2024-12-17T08:47:39Z
date available2024-12-17T08:47:39Z
date copyright24 May 2024
date issued2024
identifier other10537092.pdf
identifier urihttps://yse.yabesh.ir/std/handle/yse/336490
description abstractElectrical and mechanical performance and test requirements for on-load tap-changers of both resistor and reactor types, de-energized tap-changers, and their motor-drive mechanisms installed in power and distribution transformers, reactors, and voltage regulators are covered.
languageEnglish
publisherIEEE - The Institute of Electrical and Electronics Engineers, Inc.
titleIEEE Standard Performance Requirements and Test Methods for Tap-Changersen
titleIEEE Std C57.131-2024 (Revision of IEEE Std C57.131-2012)num
typestandard
page86
treeIEEE - The Institute of Electrical and Electronics Engineers, Inc.:;2024
contenttypefulltext
subject keywordsequalizer winding
subject keywordsreactor
subject keywordstap positions
subject keywordsdiverter switch
subject keywordsnon-bridging position
subject keywordsde-energized tap-changer (DETC)
subject keywordsthrough-current
subject keywordsIEEE C57.131
subject keywordsvacuum
subject keywordsresistor
subject keywordsmotor-drive
subject keywordstransition contacts
subject keywordsIEC 60214-2
subject keywordson-load tap-changer (OLTC)
subject keywordsIEC 60214-1
subject keywordstransfer contacts
subject keywordsvoltage regulator
subject keywordsregulating transformer
subject keywordsgas-immersed tap-changer
subject keywordsbridging position
subject keywordschange-over selector
identifier DOI10.1109/IEEESTD.2024.10537092