Standard Test Method for Measurement of Dry Film Thickness of Thin-Film Coil-Coated Systems by Destructive Means Using a Boring Device

ASTM D5796-24

Organization:
ASTM - ASTM International
Year: 2024

Abstract: 3.1 Measurement of dry film thickness of organic coatings by physically cutting through the film and optically observing and measuring the thickness offers the advantage of direct measurement as compared with nondestructive means. 3.2 Constituent coating layers can usually be measured individually by this test method, provided adhesion between each layer is sufficient. However, this can be difficult in cases where the primer, topcoat, or multiple coating layers have the same, or very similar, appearance.    A = 0.1B
URI: https://yse.yabesh.ir/std/handle/yse/340857
Collections :
  • ASTM - ASTM International
  • Download PDF : (492.2Kb)
  • Show Full MetaData Hide Full MetaData
  • Statistics

    Standard Test Method for Measurement of Dry Film Thickness of Thin-Film Coil-Coated Systems by Destructive Means Using a Boring Device

Show full item record

contributor authorASTM - ASTM International
date accessioned2025-09-30T17:59:09Z
date available2025-09-30T17:59:09Z
date copyright2024
date issued2024
identifier otherd5796-24.pdf
identifier urihttps://yse.yabesh.ir/std/handle/yse/340857
description abstract3.1 Measurement of dry film thickness of organic coatings by physically cutting through the film and optically observing and measuring the thickness offers the advantage of direct measurement as compared with nondestructive means. 3.2 Constituent coating layers can usually be measured individually by this test method, provided adhesion between each layer is sufficient. However, this can be difficult in cases where the primer, topcoat, or multiple coating layers have the same, or very similar, appearance.    A = 0.1B
languageEnglish
titleStandard Test Method for Measurement of Dry Film Thickness of Thin-Film Coil-Coated Systems by Destructive Means Using a Boring Deviceen
titleASTM D5796-24num
typestandard
statusActive
treeASTM - ASTM International:;2024
contenttypefulltext
scope1.1 This test method covers the measurement of dry film thickness (DFT) of coating films by microscopic observation of a precision-cut, shallow-angle crater bored into the coating film. This crater reveals cross sectional layers appearing as rings, whose width is proportional to the depth of the coating layer(s) and allows for direct calculation of dry film thickness. 1.1.1 The Apparatus, Procedure, and Precision and Bias discussions include Method A and Method B. Method A involves the use of an optical measurement apparatus. (This is a “first-generation” device.) Method B is a software driven second-generation measurement procedure that supersedes Method A. 1.2 The substrate may be any rigid, metallic material, such as cold-rolled steel, hot-dipped galvanized steel, aluminum, etc. The substrate must be planar with the exception of substrates exhibiting “coil set,” which may be held level by the use of the clamping tool on the drilling device. Note 1: Variations in the surface profile of the substrate may result in misrepresentative organic coating thickness readings. This condition may exist over substrates such as hot-dipped, coated steel sheet. This is true of all “precision cut” methods that are used to determine dry film thickness of organic coatings. This is why several measurements across the strip may be useful if substrate surface profile is suspect. 1.3 The range of thickness measurement is 0 μm to 89 μm (0 mils to 3.5 mils). Note 2: For DFT measurements of films greater than 89 μm  (3.5 mils), but less than 1600 μm (63 mils), a 45° borer may be used in accordance with this test method, with the exception of 6.8, where the micrometer reading would provide a direct read-out, and division by ten would be unnecessary per 4.3.1 Method A. 1.4 Measurements may be made on coil-coated sheet, certain formed products, or on test panels. 1.5 The values stated in SI units are to be regarded as the standard. The values given in parentheses are for information only. 1.6 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use. 1.7 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
identifier DOI10.1520/D5796-24