Standard Test Method for Coagulated Pentane Insolubles in Used Lubricating Oils by Paper Filtration (LMOA Method)

ASTM D7317-24

Organization:
ASTM - ASTM International
Year: 2024

Abstract: 5.1 Coagulated pentane insolubles can include oil-insoluble materials, some oil-insoluble resinous matter originating from oil or additive degradation, soot from incomplete diesel fuel combustion, or a combination of all three. 5.2 A significant change in coagulated pentane insolubles indicates a change in oil, and this could lead to lubrication system problems. 5.3 Coagulated pentane insolubles measurements can also assist in evaluating the performance characteristics of a used oil or in determining the cause of equipment failure. 5.4 High values of coagulated pentane insolubles have been associated with plugged oil filters, leading to opening of the bypass valve and circulation of unfiltered oil in the engine. This can lead to increased piston deposits, increased bearing wear, and premature engine failure.
URI: https://yse.yabesh.ir/std/handle/yse/340989
Collections :
  • ASTM - ASTM International
  • Download PDF : (614.3Kb)
  • Show Full MetaData Hide Full MetaData
  • Statistics

    Standard Test Method for Coagulated Pentane Insolubles in Used Lubricating Oils by Paper Filtration (LMOA Method)

Show full item record

contributor authorASTM - ASTM International
date accessioned2025-09-30T17:59:40Z
date available2025-09-30T17:59:40Z
date copyright2024
date issued2024
identifier otherd7317-24.pdf
identifier urihttps://yse.yabesh.ir/std/handle/yse/340989
description abstract5.1 Coagulated pentane insolubles can include oil-insoluble materials, some oil-insoluble resinous matter originating from oil or additive degradation, soot from incomplete diesel fuel combustion, or a combination of all three. 5.2 A significant change in coagulated pentane insolubles indicates a change in oil, and this could lead to lubrication system problems. 5.3 Coagulated pentane insolubles measurements can also assist in evaluating the performance characteristics of a used oil or in determining the cause of equipment failure. 5.4 High values of coagulated pentane insolubles have been associated with plugged oil filters, leading to opening of the bypass valve and circulation of unfiltered oil in the engine. This can lead to increased piston deposits, increased bearing wear, and premature engine failure.
languageEnglish
titleStandard Test Method for Coagulated Pentane Insolubles in Used Lubricating Oils by Paper Filtration (LMOA Method)en
titleASTM D7317-24num
typestandard
statusActive
treeASTM - ASTM International:;2024
contenttypefulltext
scope1.1 This test method covers the determination of coagulated pentane insolubles in used lubricating oils by a paper filtration method. 1.2 This test method was originally developed by the Fuels, Lubricants, and Environmental Committee (FL&E) of the Locomotive Maintenance Officer’s Association (LMOA).2 1.3 This test method is used primary for testing used diesel engine oils from railroad locomotive service. It may be applied to other samples types but precision, bias, and significance have not been determined for samples other than used railroad locomotive diesel engine oils. 1.4 This test method, in general, does not correlate with Test Method D893 on Insolubles in Lubricating Oils, since it uses separation by centrifugation and a more concentrated solution of anti-coagulant. 1.5 The correlation between this test method and Appendix A4 (Enhanced Thermal Gravimetric Analysis (TGA) Procedure) in Test Method D5967 has not been investigated. 1.6 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard. 1.7 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use. For specific warning statements, see 7.2, 7.3, and 7.4. 1.8 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
identifier DOI10.1520/D7317-24
DSpace software copyright © 2017-2020  DuraSpace