• 0
    • ارسال درخواست
    • حذف همه
    • Industrial Standards
    • Defence Standards
  • درباره ما
  • درخواست موردی
  • فهرست استانداردها
    • Industrial Standards
    • Defence Standards
  • راهنما
  • Login
  • لیست خرید شما 0
    • ارسال درخواست
    • حذف همه
View Item 
  •   YSE
  • Industrial Standards
  • ASTM - ASTM International
  • View Item
  •   YSE
  • Industrial Standards
  • ASTM - ASTM International
  • View Item
  • All Fields
  • Title(or Doc Num)
  • Organization
  • Year
  • Subject
Advanced Search
JavaScript is disabled for your browser. Some features of this site may not work without it.

Archive

Standard Practice for Clearance Examinations Following Lead Hazard Reduction Activities in Single Family Dwellings, in Individual Units of Multifamily Dwellings, and in Other Child-Occupied Facilities

ASTM E3074/E3074M-24

Organization:
ASTM - ASTM International
Year: 2024

Abstract: 4.1 A clearance examination of abatement areas and other areas associated with other lead-hazard control activities, or building maintenance or modification activities in single-family detached dwellings, individual units in multifamily dwellings, common areas or exterior sites, and child-occupied facilities is performed to determine that the clearance area is adequately safe for reoccupancy. 4.2 It is the responsibility of the user of this standard to assure that all regulatory, contractual and personnel requirements are met prior to conduct of a clearance examination. At a minimum, users of this standard shall be trained in its use and in safe practices for its conduct. Note 2: Authorities having jurisdiction may have certification or specific training requirements, or both. 4.3 This practice is one of a set of standards developed for lead hazard management activities. The visual assessment procedures required in this practice are found in Practice E2255/E2255M and the record keeping requirements are found in Practice E2239. 4.4 Although this practice was primarily developed for dwellings and for other child-occupied facilities, this practice may be also applied to nonresidential buildings and related structures by agreement between the client and the individual conducting the clearance examination. 4.5 This practice may be used by owners and property managers, including owner-occupants, and others responsible for maintaining facilities. It may also be used by lead hazard management consultants, construction contractors, labor groups, real estate and financial professionals, insurance organizations, legislators, regulators, and legal professionals. 4.6 This practice does not address whether lead-hazard reduction activities or other building modification or maintenance work were performed properly.
URI: https://yse.yabesh.ir/std/handle/yse/341410
Collections :
  • ASTM - ASTM International
  • Download PDF : (299.0Kb)
  • Show Full MetaData Hide Full MetaData
  • Statistics

    Standard Practice for Clearance Examinations Following Lead Hazard Reduction Activities in Single Family Dwellings, in Individual Units of Multifamily Dwellings, and in Other Child-Occupied Facilities

Show full item record

contributor authorASTM - ASTM International
date accessioned2025-09-30T18:01:23Z
date available2025-09-30T18:01:23Z
date copyright2024
date issued2024
identifier othere3074_e3074m-24.pdf
identifier urihttps://yse.yabesh.ir/std/handle/yse/341410
description abstract4.1 A clearance examination of abatement areas and other areas associated with other lead-hazard control activities, or building maintenance or modification activities in single-family detached dwellings, individual units in multifamily dwellings, common areas or exterior sites, and child-occupied facilities is performed to determine that the clearance area is adequately safe for reoccupancy. 4.2 It is the responsibility of the user of this standard to assure that all regulatory, contractual and personnel requirements are met prior to conduct of a clearance examination. At a minimum, users of this standard shall be trained in its use and in safe practices for its conduct. Note 2: Authorities having jurisdiction may have certification or specific training requirements, or both. 4.3 This practice is one of a set of standards developed for lead hazard management activities. The visual assessment procedures required in this practice are found in Practice E2255/E2255M and the record keeping requirements are found in Practice E2239. 4.4 Although this practice was primarily developed for dwellings and for other child-occupied facilities, this practice may be also applied to nonresidential buildings and related structures by agreement between the client and the individual conducting the clearance examination. 4.5 This practice may be used by owners and property managers, including owner-occupants, and others responsible for maintaining facilities. It may also be used by lead hazard management consultants, construction contractors, labor groups, real estate and financial professionals, insurance organizations, legislators, regulators, and legal professionals. 4.6 This practice does not address whether lead-hazard reduction activities or other building modification or maintenance work were performed properly.
languageEnglish
titleStandard Practice for Clearance Examinations Following Lead Hazard Reduction Activities in Single Family Dwellings, in Individual Units of Multifamily Dwellings, and in Other Child-Occupied Facilitiesen
titleASTM E3074/E3074M-24num
typestandard
statusActive
treeASTM - ASTM International:;2024
contenttypefulltext
scope1.1 This practice covers visual assessment for the presence of deteriorated paint, surface dust, painted debris, and paint chips with environmental sampling of surface dust to determine whether a lead hazard exists at the time of sample collection, following lead-hazard reduction activities, or other building maintenance and modification activities. 1.2 This practice addresses clearance examination of single-family detached dwellings (including exterior structures, such as fences), individual units in multifamily dwellings, common areas or exterior sites, and child-occupied facilities. 1.3 This practice also addresses clearance examinations that may include soil sampling, for example when soil abatement has been performed. 1.4 This practice includes a procedure for determining whether regulatory requirements for lead clearance levels for dust and, where warranted, soil have been met, and consequently, whether a clearance area passes or fails a clearance examination. Note 1: This practice is based on that portion of “clearance” described for the United States in 40 CFR Part 745 for abatement, and in 24 CFR Part 35 for lead-hazard reduction activities other than abatement. 1.5 The values stated in either SI units or inch-pound units are to be regarded separately as standard. The values stated in each system are not necessarily exact equivalents; therefore, to ensure conformance with the standard, each system shall be used independently of the other, and values from the two systems shall not be combined. 1.6 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use. 1.7 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
identifier DOI10.1520/E3074_E3074M-24
DSpace software copyright © 2017-2020  DuraSpace
نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
yabeshDSpacePersian
 
DSpace software copyright © 2017-2020  DuraSpace
نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
yabeshDSpacePersian