Standard Specification for Wrought Seamless and Welded and Drawn Cobalt Alloy Small Diameter Tubing for Surgical Implants (UNS R30003, UNS R30008, UNS R30035, UNS R30605, and UNS R31537)

ASTM F2527-24

Organization:
ASTM - ASTM International
Year: 2024

Abstract: This specification covers the requirements for wrought seamless and welded and drawn cobalt alloy small diameter tubing used for the manufacture of surgical implants. Product variables that differentiate small diameter medical tubing from the bar, wire, sheet, and strip product forms are addressed. This specification applies to straight length tubing of specified diameters and thickness. Seamless tubing shall be made from bar, hollow bar, rod, or hollow rod raw material forms through a prescribed process. Welded and drawn tubing shall be made from strip or sheet raw material forms that meet the specified chemical requirements. The tubing shall be subject to tensile testing.
URI: https://yse.yabesh.ir/std/handle/yse/341642
Collections :
  • ASTM - ASTM International
  • Download PDF : (286.7Kb)
  • Show Full MetaData Hide Full MetaData
  • Statistics

    Standard Specification for Wrought Seamless and Welded and Drawn Cobalt Alloy Small Diameter Tubing for Surgical Implants (UNS R30003, UNS R30008, UNS R30035, UNS R30605, and UNS R31537)

Show full item record

contributor authorASTM - ASTM International
date accessioned2025-09-30T18:02:18Z
date available2025-09-30T18:02:18Z
date copyright2024
date issued2024
identifier otherf2527-24.pdf
identifier urihttps://yse.yabesh.ir/std/handle/yse/341642
description abstractThis specification covers the requirements for wrought seamless and welded and drawn cobalt alloy small diameter tubing used for the manufacture of surgical implants. Product variables that differentiate small diameter medical tubing from the bar, wire, sheet, and strip product forms are addressed. This specification applies to straight length tubing of specified diameters and thickness. Seamless tubing shall be made from bar, hollow bar, rod, or hollow rod raw material forms through a prescribed process. Welded and drawn tubing shall be made from strip or sheet raw material forms that meet the specified chemical requirements. The tubing shall be subject to tensile testing.
languageEnglish
titleStandard Specification for Wrought Seamless and Welded and Drawn Cobalt Alloy Small Diameter Tubing for Surgical Implants (UNS R30003, UNS R30008, UNS R30035, UNS R30605, and UNS R31537)en
titleASTM F2527-24num
typestandard
statusActive
treeASTM - ASTM International:;2024
contenttypefulltext
scope1.1 This specification covers the requirements for wrought seamless and welded and drawn cobalt alloy small diameter tubing used for the manufacture of surgical implants. Material shall conform to the applicable requirements of Specifications F90, F562, F688, F1058 or F1537, Alloy 1. This specification addresses those product variables that differentiate small diameter medical tubing from the bar, wire, sheet, and strip product forms covered in these specifications. 1.2 This specification applies to straight length tubing with 6.3 mm [0.250 in.] and smaller nominal outside diameter (OD) and 0.76 mm [0.030 in.] and thinner nominal wall thickness. 1.3 The specifications in 2.1 are referred to as the ASTM material standard(s) in this specification. 1.4 The values stated in either SI units or inch-pound units are to be regarded separately as standard. The values stated in each system are not necessarily exact equivalents; therefore, to ensure conformance with the standard, each system shall be used independently of the other, and values from the two systems shall not be combined. 1.5 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use. 1.6 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
identifier DOI10.1520/F2527-24