Standard Test Methods for Detection of Cuprous Oxide (Hydrogen Embrittlement Susceptibility) in Copper
ASTM B577-24
Organization:
ASTM - ASTM International
Year: 2024
Abstract: 5.1 These test methods determine whether copper products will be resistant to embrittlement when exposed to elevated temperatures in a reducing atmosphere. 5.1.1 It is assumed that all who use these test methods will be trained personnel capable of performing these procedures skillfully and safely. It is expected that work will be performed in a properly equipped facility.
Collections
:
-
Statistics
Standard Test Methods for Detection of Cuprous Oxide (Hydrogen Embrittlement Susceptibility) in Copper
Show full item record
| contributor author | ASTM - ASTM International | |
| date accessioned | 2025-09-30T18:06:16Z | |
| date available | 2025-09-30T18:06:16Z | |
| date copyright | 2024 | |
| date issued | 2024 | |
| identifier other | b0577-24.pdf | |
| identifier uri | https://yse.yabesh.ir/std/handle/yse/342366 | |
| description abstract | 5.1 These test methods determine whether copper products will be resistant to embrittlement when exposed to elevated temperatures in a reducing atmosphere. 5.1.1 It is assumed that all who use these test methods will be trained personnel capable of performing these procedures skillfully and safely. It is expected that work will be performed in a properly equipped facility. | |
| language | English | |
| title | Standard Test Methods for Detection of Cuprous Oxide (Hydrogen Embrittlement Susceptibility) in Copper | en |
| title | ASTM B577-24 | num |
| type | standard | |
| status | Active | |
| tree | ASTM - ASTM International:;2024 | |
| contenttype | fulltext | |
| scope | 1.1 These test methods cover procedures for determining the presence of cuprous oxide (Cu2O) in products made from deoxidized and oxygen-free copper. 1.2 The test methods appear in the following order: Sections Microscopical Examination without Thermal Treatment 9 – 11 Microscopical Examination after Thermal Treatment 13 – 15 Closed Bend Test after Thermal Treatment 17 – 19 Reverse Bend Test after Thermal Treatment 21 – 23 1.3 Units—The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard. 1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use. 1.5 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee. | |
| identifier DOI | 10.1520/B0577-24 |