Standard Test Method for Thermal Conductivity of Insulating Firebrick
ASTM C182-24
Organization:
ASTM - ASTM International
Year: 2024
Abstract: 3.1 The thermal conductivity of insulating firebrick (IFB) is a property required for the selection of IFB for a specific thermal performance. Users select brick to provide a specified heat-loss and cold-face temperature without exceeding the temperature limitation of the brick. This test method establishes placement of thermocouples and the positioning of test specimens in the calorimeter. 3.2 This procedure must be used with Test Method C201 and requires a large thermal gradient and steady-state conditions. The results are based upon a mean temperature. 3.3 The data from this test method are suitable for specification acceptance, estimating heat loss and surface temperature, and design of multi-layer refractory construction. 3.4 The use of these data requires consideration of the actual application environment and conditions.
Collections
:
-
Statistics
Standard Test Method for Thermal Conductivity of Insulating Firebrick
Show full item record
| contributor author | ASTM - ASTM International | |
| date accessioned | 2025-09-30T18:06:51Z | |
| date available | 2025-09-30T18:06:51Z | |
| date copyright | 2024 | |
| date issued | 2024 | |
| identifier other | c0182-24.pdf | |
| identifier uri | https://yse.yabesh.ir/std/handle/yse/342428 | |
| description abstract | 3.1 The thermal conductivity of insulating firebrick (IFB) is a property required for the selection of IFB for a specific thermal performance. Users select brick to provide a specified heat-loss and cold-face temperature without exceeding the temperature limitation of the brick. This test method establishes placement of thermocouples and the positioning of test specimens in the calorimeter. 3.2 This procedure must be used with Test Method C201 and requires a large thermal gradient and steady-state conditions. The results are based upon a mean temperature. 3.3 The data from this test method are suitable for specification acceptance, estimating heat loss and surface temperature, and design of multi-layer refractory construction. 3.4 The use of these data requires consideration of the actual application environment and conditions. | |
| language | English | |
| title | Standard Test Method for Thermal Conductivity of Insulating Firebrick | en |
| title | ASTM C182-24 | num |
| type | standard | |
| status | Active | |
| tree | ASTM - ASTM International:;2024 | |
| contenttype | fulltext | |
| scope | 1.1 This test method supplements Test Method C201, and shall be used in conjunction with that test method to determine the thermal conductivity of insulating firebrick. 1.2 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard. 1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use. 1.4 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee. | |
| identifier DOI | 10.1520/C0182-24 |