Standard Practice for Use of Sealants in Acoustical Applications

ASTM C919-24

Organization:
ASTM - ASTM International
Year: 2024

Abstract: 4.1 Walls, ceilings, and floors in building construction with improperly sealed joints, voids, or penetrations will not achieve the desired sound transmission loss. Proper sealing of joints, voids, and penetrations will increase sound transmission loss by reducing airborne sound flanking paths.
URI: https://yse.yabesh.ir/std/handle/yse/342500
Collections :
  • ASTM - ASTM International
  • Download PDF : (771.3Kb)
  • Show Full MetaData Hide Full MetaData
  • Statistics

    Standard Practice for Use of Sealants in Acoustical Applications

Show full item record

contributor authorASTM - ASTM International
date accessioned2025-09-30T18:07:18Z
date available2025-09-30T18:07:18Z
date copyright2024
date issued2024
identifier otherc0919-24.pdf
identifier urihttps://yse.yabesh.ir/std/handle/yse/342500
description abstract4.1 Walls, ceilings, and floors in building construction with improperly sealed joints, voids, or penetrations will not achieve the desired sound transmission loss. Proper sealing of joints, voids, and penetrations will increase sound transmission loss by reducing airborne sound flanking paths.
languageEnglish
titleStandard Practice for Use of Sealants in Acoustical Applicationsen
titleASTM C919-24num
typestandard
statusActive
treeASTM - ASTM International:;2024
contenttypefulltext
scope1.1 This practice provides information for the use of sealants to reduce sound transmission characteristics of interior walls, ceilings, and floors by proper application of sealants to joints, voids, and penetrations normally found in building construction, which are commonly referred to as airborne sound flanking paths. 1.2 The committee with jurisdiction over this standard is not aware of any comparable standards published by other organizations. 1.3 The values stated in SI units are to be regarded as standard. The values given in parentheses after SI units are provided for information only and are not considered standard. 1.4 This standard does not purport to address fire stopping or safing requirements for joints, voids, and penetrations through fire-rated wall, ceiling, and floor assemblies. Additional requirements may be necessary for fire-rated assemblies to meet the applicable building code provisions. 1.5 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use. 1.6 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
identifier DOI10.1520/C0919-24
DSpace software copyright © 2017-2020  DuraSpace
نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
yabeshDSpacePersian
 
DSpace software copyright © 2017-2020  DuraSpace
نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
yabeshDSpacePersian