Standard Test Method for Time of Setting of Grouts for Preplaced-Aggregate Concrete in the Laboratory

ASTM C953-24

Organization:
ASTM - ASTM International
Year: 2024

Abstract: 5.1 This test method determines the time of setting of grout mixed to the fluid consistency required for its use in PA concrete. 5.2 The time of setting is also useful in determining the acceptability of components of grout that must be mixed to the fluid consistency required for production of PA concrete.
URI: https://yse.yabesh.ir/std/handle/yse/342506
Collections :
  • ASTM - ASTM International
  • Download PDF : (256.8Kb)
  • Show Full MetaData Hide Full MetaData
  • Statistics

    Standard Test Method for Time of Setting of Grouts for Preplaced-Aggregate Concrete in the Laboratory

Show full item record

contributor authorASTM - ASTM International
date accessioned2025-09-30T18:07:20Z
date available2025-09-30T18:07:20Z
date copyright2024
date issued2024
identifier otherc0953-24.pdf
identifier urihttps://yse.yabesh.ir/std/handle/yse/342506
description abstract5.1 This test method determines the time of setting of grout mixed to the fluid consistency required for its use in PA concrete. 5.2 The time of setting is also useful in determining the acceptability of components of grout that must be mixed to the fluid consistency required for production of PA concrete.
languageEnglish
titleStandard Test Method for Time of Setting of Grouts for Preplaced-Aggregate Concrete in the Laboratoryen
titleASTM C953-24num
typestandard
statusActive
treeASTM - ASTM International:;2024
contenttypefulltext
scope1.1 This method covers the determination test of time of setting of hydraulic cement grout mixtures used in preplaced-aggregate (PA) concrete using the Vicat apparatus. 1.2 The text of this standard refers to notes and footnotes that provide explanatory material. These notes and footnotes (excluding those in tables and figures) shall not be considered as requirements of this standard. 1.3 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard. 1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.Warning—Fresh hydraulic cementitious mixtures are caustic and may cause chemical burns to skin and tissue upon prolonged exposure.2 1.5 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
identifier DOI10.1520/C0953-24
DSpace software copyright © 2017-2020  DuraSpace