• 0
    • ارسال درخواست
    • حذف همه
    • Industrial Standards
    • Defence Standards
  • درباره ما
  • درخواست موردی
  • فهرست استانداردها
    • Industrial Standards
    • Defence Standards
  • راهنما
  • Login
  • لیست خرید شما 0
    • ارسال درخواست
    • حذف همه
View Item 
  •   YSE
  • Industrial Standards
  • ASTM - ASTM International
  • View Item
  •   YSE
  • Industrial Standards
  • ASTM - ASTM International
  • View Item
  • All Fields
  • Title(or Doc Num)
  • Organization
  • Year
  • Subject
Advanced Search
JavaScript is disabled for your browser. Some features of this site may not work without it.

Archive

Standard Specification for Glazing and Glazing Systems Subject to Airblast Loadings

ASTM F2912-25

Organization:
ASTM - ASTM International
Year: 2025

Abstract: This specification covers exterior windows, glazing panels, glazed curtain walls, and other glazed protective systems used in buildings that may be subjected to intentional and accidental explosions. The specification is designed for all glazing, glazing systems, and glazing retrofit systems such as those fabricated from glass, glass-clad plastics, plastic, laminated glass, glass/plastic glazing materials, and organic coated glass.
URI: https://yse.yabesh.ir/std/handle/yse/342945
Collections :
  • ASTM - ASTM International
  • Download PDF : (282.9Kb)
  • Show Full MetaData Hide Full MetaData
  • Statistics

    Standard Specification for Glazing and Glazing Systems Subject to Airblast Loadings

Show full item record

contributor authorASTM - ASTM International
date accessioned2025-09-30T19:20:40Z
date available2025-09-30T19:20:40Z
date copyright2025
date issued2025
identifier otherf2912-25.pdf
identifier urihttps://yse.yabesh.ir/std/handle/yse/342945
description abstractThis specification covers exterior windows, glazing panels, glazed curtain walls, and other glazed protective systems used in buildings that may be subjected to intentional and accidental explosions. The specification is designed for all glazing, glazing systems, and glazing retrofit systems such as those fabricated from glass, glass-clad plastics, plastic, laminated glass, glass/plastic glazing materials, and organic coated glass.
languageEnglish
titleStandard Specification for Glazing and Glazing Systems Subject to Airblast Loadingsen
titleASTM F2912-25num
typestandard
statusActive
treeASTM - ASTM International:;2025
contenttypefulltext
scope1.1 This specification covers glazing, glazed windows, glazed curtain walls, glazing panels in doors, other glazed protective systems, and non-attached window retrofit systems used in buildings that may be subjected to intentional or accidental explosions. 1.2 This specification addresses only glazing, glazing systems, and glazing retrofit systems. This specification does not address the structural integrity and functionality of door assemblies. It assumes that the designer has verified that other structural elements have been adequately designed or tested to resist the anticipated airblast loads. 1.3 This specification is designed for all glazing, glazing systems, and glazing retrofit systems including, but not limited to, those fabricated from glass, plastic, glass-clad plastics, laminated glass, glass/plastic glazing materials, organic coated glass (filmed), and non-attached glazing retrofit systems such as blast curtains, cables, shades, and architectural mesh. 1.4 This specification does not determine the assessment of a facility nor acceptable hazard ratings. Threat and risk assessment shall have already been performed and the acceptable hazard rating defined. The hazard rating should be selected taking into account the installed position of the glazing. Glazing at higher elevations relative to the floor may require more stringent hazard considerations. 1.5 This specification determines the hazard rating associated with blast tested glazing, glazing systems, and non-attached glazing retrofit systems. In addition to glazing fragments and system components creating hazards, glazing slivers are also included as part of the hazard rating. The inclusion of slivers may cause a worse hazard rating than is predicted when using analytical approaches such as presented in Practice F2248 or in other methods. 1.6 The values stated in SI units are to be regarded as the standard. Values given in parentheses are for information only. For conversion of quantities in various systems of measurements to SI units, see IEEE/ASTM SI 10. 1.7 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use. 1.8 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
identifier DOI10.1520/F2912-25
DSpace software copyright © 2017-2020  DuraSpace