NASA-LLIS-0434

Lessons Learned – Rusty Integrated Circuits (~1973)

Organization:
NASA - National Aeronautics and Space Administration (NASA)
Year: 1996

Abstract: Abstract:
During the Viking program, rust spots were observed on the gold-plated Kovar lids of a number of flat pack ICs. The cause was suspected to be chlorine from the lead tinning operation, and various polymeric coatings failed to prevent further corrosion.
Following the use of any chlorinated product, a thorough and complete cleaning to remove all residual chlorine contamination is a necessity.
URI: https://yse.yabesh.ir/std/handle/yse/36009
Subject: Hardware
Collections :
  • NASA - National Aeronautics and Space Administration (NASA)
  • Download PDF : (13.11Kb)
  • Show Full MetaData Hide Full MetaData
  • Statistics

    NASA-LLIS-0434

Show full item record

contributor authorNASA - National Aeronautics and Space Administration (NASA)
date accessioned2017-09-04T15:34:16Z
date available2017-09-04T15:34:16Z
date copyright07/17/1996
date issued1996
identifier otherOMBEQCAAAAAAAAAA.pdf
identifier urihttps://yse.yabesh.ir/std/handle/yse/36009
description abstractAbstract:
During the Viking program, rust spots were observed on the gold-plated Kovar lids of a number of flat pack ICs. The cause was suspected to be chlorine from the lead tinning operation, and various polymeric coatings failed to prevent further corrosion.
Following the use of any chlorinated product, a thorough and complete cleaning to remove all residual chlorine contamination is a necessity.
languageEnglish
titleNASA-LLIS-0434num
titleLessons Learned – Rusty Integrated Circuits (~1973)en
typestandard
page2
statusActive
treeNASA - National Aeronautics and Space Administration (NASA):;1996
contenttypefulltext
subject keywordsHardware
subject keywordsParts Materials & Processes
DSpace software copyright © 2017-2020  DuraSpace
نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
yabeshDSpacePersian
 
DSpace software copyright © 2017-2020  DuraSpace
نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
yabeshDSpacePersian