TIA TIA-4963

Electrical Characteristic of Generators and Receivers with Reversed-Wire Immunity for Use in Balanced Digital Multipoint Systems

Organization:
TIA - Telecommunications Industry Association
Year: 2013

Abstract: This Standard specifies the electrical characteristics of generators and receivers that may be employed when specified for the interchange of binary signals in multipoint interconnection of digital equipment. When implemented within the guidelines of this Standard, multiple generators and receivers may be attached to a common interconnecting cable. The generators and receivers operate with no errors if the balanced interconnecting cables are connected normally or with the differential signal wires reversed.
An interchange system includes one or more generators connected by a balanced interconnecting cable to one or more receivers with or without terminating resistors. The electrical characteristics of the circuit are specified in terms of the required voltage, current, and resistance values obtained by measurements at the equipment interconnect points.
This Standard does not specify other characteristics, such as signal quality, timing, protocol, pin assignments, power supply voltage, operating temperature range, etc., that are essential for proper operation of interconnected equipment. Any devices complying with this Standard shall do so within the ranges of those factors appropriate for the device operation, such as power supply voltages, and ambient temperature. It is intended that this Standard be referenced by other standards and specifications that specify the additional characteristics necessary to assure satisfactory interoperation of equipment.
URI: https://yse.yabesh.ir/std/handle/yse/40129
Collections :
  • TIA - Telecommunications Industry Association
  • Download PDF : (382.1Kb)
  • Show Full MetaData Hide Full MetaData
  • Statistics

    TIA TIA-4963

Show full item record

contributor authorTIA - Telecommunications Industry Association
date accessioned2017-09-04T15:38:06Z
date available2017-09-04T15:38:06Z
date copyright04/01/2013
date issued2013
identifier otherOXDCCFAAAAAAAAAA.pdf
identifier urihttps://yse.yabesh.ir/std/handle/yse/40129
description abstractThis Standard specifies the electrical characteristics of generators and receivers that may be employed when specified for the interchange of binary signals in multipoint interconnection of digital equipment. When implemented within the guidelines of this Standard, multiple generators and receivers may be attached to a common interconnecting cable. The generators and receivers operate with no errors if the balanced interconnecting cables are connected normally or with the differential signal wires reversed.
An interchange system includes one or more generators connected by a balanced interconnecting cable to one or more receivers with or without terminating resistors. The electrical characteristics of the circuit are specified in terms of the required voltage, current, and resistance values obtained by measurements at the equipment interconnect points.
This Standard does not specify other characteristics, such as signal quality, timing, protocol, pin assignments, power supply voltage, operating temperature range, etc., that are essential for proper operation of interconnected equipment. Any devices complying with this Standard shall do so within the ranges of those factors appropriate for the device operation, such as power supply voltages, and ambient temperature. It is intended that this Standard be referenced by other standards and specifications that specify the additional characteristics necessary to assure satisfactory interoperation of equipment.
languageEnglish
titleTIA TIA-4963num
titleElectrical Characteristic of Generators and Receivers with Reversed-Wire Immunity for Use in Balanced Digital Multipoint Systemsen
typestandard
page30
statusActive
treeTIA - Telecommunications Industry Association:;2013
contenttypefulltext
DSpace software copyright © 2017-2020  DuraSpace
نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
yabeshDSpacePersian
 
DSpace software copyright © 2017-2020  DuraSpace
نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
yabeshDSpacePersian