Show simple item record

Lessons Learned - Preventive Shop Practices

contributor authorNASA - National Aeronautics and Space Administration (NASA)
date accessioned2017-09-04T15:39:26Z
date available2017-09-04T15:39:26Z
date copyright07/15/1999
date issued1999
identifier otherPAVEQCAAAAAAAAAA.pdf
identifier urihttps://yse.yabesh.ir/std/handle/yse/41511
description abstractDescription of Driving Event:
Technicians were trimming composite material using a table saw with a diamond-cutting blade. After trimming the employees took a break. When returning they discovered smoke in the room which appeared to be coming from inside the table saw. One technician disconnected the main power switch, while the other pulled the Fire Alarm. There were no injuries to personnel or damage equipment.
Root cause: An investigation found that the composite dust had accumulated in the base of the table saw. There was a failure found in the machine dust collection system, which would not allow the removal of dust/material during cutting. The smoke was ignited by heat or spark during the cutting process.
languageEnglish
titleNASA-LLIS-1209num
titleLessons Learned - Preventive Shop Practicesen
typestandard
page2
statusActive
treeNASA - National Aeronautics and Space Administration (NASA):;1999
contenttypefulltext
subject keywordsFacilities
subject keywordsGround Equipment
subject keywordsGround Operations
subject keywordsIndustrial Operations
subject keywordsParts Materials & Processes
subject keywordsRisk Management/Assessment