NASA-LLIS-1209
Lessons Learned - Preventive Shop Practices
Year: 1999
Abstract: Description of Driving Event:
Technicians were trimming composite material using a table saw with a diamond-cutting blade. After trimming the employees took a break. When returning they discovered smoke in the room which appeared to be coming from inside the table saw. One technician disconnected the main power switch, while the other pulled the Fire Alarm. There were no injuries to personnel or damage equipment.
Root cause: An investigation found that the composite dust had accumulated in the base of the table saw. There was a failure found in the machine dust collection system, which would not allow the removal of dust/material during cutting. The smoke was ignited by heat or spark during the cutting process.
Technicians were trimming composite material using a table saw with a diamond-cutting blade. After trimming the employees took a break. When returning they discovered smoke in the room which appeared to be coming from inside the table saw. One technician disconnected the main power switch, while the other pulled the Fire Alarm. There were no injuries to personnel or damage equipment.
Root cause: An investigation found that the composite dust had accumulated in the base of the table saw. There was a failure found in the machine dust collection system, which would not allow the removal of dust/material during cutting. The smoke was ignited by heat or spark during the cutting process.
Subject: Facilities
Show full item record
| contributor author | NASA - National Aeronautics and Space Administration (NASA) | |
| date accessioned | 2017-09-04T15:39:26Z | |
| date available | 2017-09-04T15:39:26Z | |
| date copyright | 07/15/1999 | |
| date issued | 1999 | |
| identifier other | PAVEQCAAAAAAAAAA.pdf | |
| identifier uri | https://yse.yabesh.ir/std/handle/yse/41511 | |
| description abstract | Description of Driving Event: Technicians were trimming composite material using a table saw with a diamond-cutting blade. After trimming the employees took a break. When returning they discovered smoke in the room which appeared to be coming from inside the table saw. One technician disconnected the main power switch, while the other pulled the Fire Alarm. There were no injuries to personnel or damage equipment. Root cause: An investigation found that the composite dust had accumulated in the base of the table saw. There was a failure found in the machine dust collection system, which would not allow the removal of dust/material during cutting. The smoke was ignited by heat or spark during the cutting process. | |
| language | English | |
| title | NASA-LLIS-1209 | num |
| title | Lessons Learned - Preventive Shop Practices | en |
| type | standard | |
| page | 2 | |
| status | Active | |
| tree | NASA - National Aeronautics and Space Administration (NASA):;1999 | |
| contenttype | fulltext | |
| subject keywords | Facilities | |
| subject keywords | Ground Equipment | |
| subject keywords | Ground Operations | |
| subject keywords | Industrial Operations | |
| subject keywords | Parts Materials & Processes | |
| subject keywords | Risk Management/Assessment |